Une simulation numérique sur les phénomènes de recirculation du panache généré par les obstacles situés autour d'une rangée de tours de refroidissement.
A numerical simulation on recirculation phenomena of the plume generated by obstacles around a row of cooling towers.
Auteurs : LEE J. H., MOSHFEGHIAN M., CHI K. Y., et al.
Type d'article : Article
Résumé
The present paper addresses the recirculation phenomena of the plume generated by obstacles around a row of cross-flow type forced draft cooling towers. In order to consider the interaction between external and internal flow of the cooling tower, both outside and inside of the cooling tower are involved in a computational domain. A three-dimensional in-house program based on a non-orthogonal, non-staggered and unstructured grid system is employed. The standard kee turbulence model is used for the turbulent effect. In order to analyze flow and heat/mass transfers in the cooling tower, the continuity, momentum, moisture fraction and enthalpy equations have been considered for both air and water. The density and moisture fraction for air and water are obtained by using the function of thermal properties. The geometrical parameters investigated in this research are the height of obstacle, the distance between the inlet region of cooling tower and the obstacle wall, existence of the air-guide and effects of front and rear obstacles. The results show that the mean moisture fractions in the cases with air-guide are, in general, lower than the cases without air-guide under the same conditions. Also, in the cases without airguide, the mean moisture fraction increases as the obstacle height increases. In addition, it is observed that for the cases without the air-guide with the increase in the distance between the tower and obstacle, the mean moisture fraction is decreased. However, the cases with air-guide do not follow a specific pattern in the same situations.
Détails
- Titre original : A numerical simulation on recirculation phenomena of the plume generated by obstacles around a row of cooling towers.
- Identifiant de la fiche : 30013883
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 72 - n. 1
- Date d'édition : 11/2014
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2014.04.021
Liens
Voir d'autres articles du même numéro (1)
Voir la source
Indexation
-
Flow and heat transfer characteristics of indir...
- Auteurs : WU X. P., YANG L. J., DU X. Z., et al.
- Date : 05/2014
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 79
Voir la fiche
-
Performance optimization of coupled heat and ma...
- Auteurs : JIANG J., ZHANG L., LIU X., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Exergy based performance analysis of a shower c...
- Auteurs : QI X., LIU Y., LIU Z.
- Date : 04/2013
- Langues : Anglais
- Source : Strojniski vestnik - Journal of mechanical Engineering - vol. 59 - n. 4
- Formats : PDF
Voir la fiche
-
Study of a counterflow wet cooling tower. I. Si...
- Auteurs : IOSIFESCU C., TOFAN S.
- Date : 2012
- Langues : Anglais
- Source : Buletinul Institutului politehnic din Iasi, Sectia Constructii de Masini - vol. 58 - n. 3
Voir la fiche
-
Influence of ambient conditions and water flow ...
- Auteurs : HE S., GUAN Z., GURGENCI H., et al.
- Date : 05/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 66 - n. 1-2
Voir la fiche