Une stratégie pour optimiser la quantité de charge du frigorigène mixte pour le refroidisseur Joule-Thomson.

A strategy to optimize the charge amount of the mixed refrigerant for the Joule-Thomson cooler.

Auteurs : PANG W., LIU J., XU X.

Type d'article : Article, Article de la RIF

Résumé

The performance of the mixed refrigerant (MR) Joule–Thomson cooler is mainly dependent on the MR circulation composition for a given hardware. However, it is difficult to charge the MR to the desired circulation composition, due to the composition shift. In the present study, a novel strategy was proposed to solve this problem. In this strategy, the MR Joule–Thomson cooler is first charged with the initial charge amount, which is obtained by estimating the MR inventory in the cooler using the homogeneous model. Afterwards, the cooler is started and the MR circulation composition is adjusted to the corresponding optimal composition by adding the MR charge amount stepwise. Additionally, this strategy was verified by an experiment with a ternary mixture of methane, ethane and i-butane. The experimental results indicated that the MR circulation composition was able to be adjusted to the corresponding optimal circulation composition approximately within the relative deviation of ±5%.

Documents disponibles

Format PDF

Pages : 466-479

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A strategy to optimize the charge amount of the mixed refrigerant for the Joule-Thomson cooler.
  • Identifiant de la fiche : 30018613
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
  • Date d'édition : 09/2016

Liens


Voir d'autres articles du même numéro (37)
Voir la source