Document IIF

Utilisation d’un cycle combinant refroidissement et génération d’électricité dans un système de production/liquéfaction de H2 à partir d’eau dessalée intégrant une configuration géothermique durable : optimisation multifacette à l’aide de l’IA et analyse économique.

Employing cooling/power cycle in a sustainable geothermal scheme integrated desalinated water-based H2 production/liquefaction; AI-aided multi-facet optimization and economic examination.

Résumé

The sustainable nature of geothermal energy, combined with advances in power generation technologies, has allowed establishing sustainable energy supply programs. To respond to significant thermal losses, it is crucial to develop hybrid systems that minimize irreversibility through environmentally friendly methods, which is vital for the longevity of these energy conversion processes. Thus, this study introduces an innovative environmentally friendly thermal plan that identifies and addresses points of thermal losses in a geothermal power cycle. The process employs a multi-step approach for producing desalinated water, converting it into hydrogen, and subsequently liquefying hydrogen gas. The suggested scheme incorporates subsystems, encompassing a geothermal flash cycle, an organic flash cycle, a unit for thermally produced desalinated water, a combined cooling and power cycle, a water electrolysis module, and a Claude cycle. This research assesses the thermodynamic, cost, and sustainability viewpoints. The research’s primary aim is to optimize the system’s performance using an artificial intelligence-driven optimization algorithm. The optimization targets the cost of liquefied hydrogen and exergy efficiency as objective functions, employing artificial neural networks that achieve a regression coefficient of 1 to initiate the optimization process. Using the NSGA-II algorithm, four decision variables are utilized to map the Pareto front, revealing an optimum exergetic efficiency of 0.3208 and a liquefied hydrogen cost of 0.3676 $/lit. The hydrogen liquefaction rate is attained at 44.57 lit/h, resulting in a sustainability index of 1.472.

Documents disponibles

Format PDF

Pages : 20 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Employing cooling/power cycle in a sustainable geothermal scheme integrated desalinated water-based H2 production/liquefaction; AI-aided multi-facet optimization and economic examination.
  • Identifiant de la fiche : 30034391
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 177
  • Date d'édition : 09/2025
  • DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2025.06.016

Liens


Voir d'autres articles du même numéro (34)
Voir la source

Indexation

  • Thèmes : N/A
  • Mots-clés : N/A