Utilisation du R417A (Isceon 59) pour les applications relatives au froid et au conditionnement d'air.
Use of R417A (Isceon 59) in refrigeration and air conditioning applications.
Auteurs : ROBERTS N. A.
Résumé
With the phase-out of HCFCs being accelerated in some regions of the world, most notably Europe, many studies have been performed on two alternatives to replace R22, i.e. R407C and R410A. However, there is a third alternative emerging as a candidate to replace R22, namely R417A comprising R125, R134a and R600. R417A has been primarily developed to replace R22 in air conditioning applications but has also been successfully utilized in refrigeration applications such as commercial refrigeration display cabinets. It is the only zero ODP replacement with an A1/A1 ASHRAE classification that can be used with mineral, alkylbenzene or fully synthetic lubricants. The paper details some practical examples of the use of R417A in air conditioning, refrigeration and heat pump applications.
Détails
- Titre original : Use of R417A (Isceon 59) in refrigeration and air conditioning applications.
- Identifiant de la fiche : 2002-2241
- Langues : Anglais
- Source : Le ultime tecnologie del freddo e del condizionamento./ Latest technologies in refrigeration and air conditioning.
- Date d'édition : 29/06/2001
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (40)
Voir le compte rendu de la conférence
Indexation
-
Retrofitting R22 systems.
- Auteurs : ROBERTS N.
- Date : 01/11/2001
- Langues : Anglais
- Source : Efficient air conditioning: the role of refrigeration. Conference proceedings.
Voir la fiche
-
Use of R417A in refrigeration and air condition...
- Auteurs : ROBERTS N. A.
- Date : 01/04/2001
- Langues : Anglais
- Source : Arab-African Conference for Refrigeration and Air Conditioning.
Voir la fiche
-
Experience of using hydrocarbons in refrigerati...
- Auteurs : POWELL L., BLACKLOCK P.
- Date : 07/1998
- Langues : Anglais
- Source : AIRAH J. - vol. 52 - n. 7
Voir la fiche
-
Exemples d'applications avec l'ammoniac : situa...
- Auteurs : KIEFFER M.
- Date : 06/02/2002
- Langues : Français
- Source : Alternatives au R22 en génie climatique : avantages et inconvénients. Journée française du Froid : recueil des conférences.
Voir la fiche
-
Ventilation silencieuse.
- Auteurs : ABBIATI F.
- Date : 1992
- Langues : Italien
- Source : Riv. Tecnol. aliment. - vol. 3 - n. 8
Voir la fiche