Document IIF
Validation de modèles avancés d’échangeurs de chaleur à tubes à ailettes avec fonctionnalité de conduction inter-ailettes.
Validation of advanced fin-and-tube heat exchanger models with cross-fin conduction functionality.
Auteurs : SARFRAZ O., BACH C. K., BRADSHAW C. R.
Type d'article : Article de la RIF
Résumé
A variety of fin-and-tube heat exchanger models have been developed to predict heat exchangers’ performance metrics (e.g. capacity). Prediction of performance metrics of heat exchangers with these features are significantly less accurate without consideration of cross-fin conduction.
This work presents a validation of two different heat exchanger models that considers the cross-fin conduction against two-phase refrigerant data. The first heat exchanger model i.e. cross-fin model is a detailed segment-by-segment model while the second model i.e. fin discretized model is a reduced order segment-by-segment model.
An experimental facility was established to obtain two-phase experimental data that can test the evaporator or condenser coil up to 17.6 kW (5 tons) capacity. An 8-circuit fin-and-tube heat exchanger was custom manufactured for validation purposes, and was tested in the facility. The model results are compared against the experimental data obtained for the following cases: 7 active circuits, 4 active circuits, and 3 active circuits that have refrigerant flow in their tubes. The cross-fin model with the consideration of cross-fin conduction and fin discretized model predicted the experimental capacity within 0–8% for all test cases. However, the maximum difference in capacity predicted by cross-fin model without cross-fin conduction consideration from the experimental capacity was more than 30% for 3 active circuits.
Documents disponibles
Format PDF
Pages : 70-81
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Validation of advanced fin-and-tube heat exchanger models with cross-fin conduction functionality.
- Identifiant de la fiche : 30027492
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 116
- Date d'édition : 08/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.03.020
Liens
Voir d'autres articles du même numéro (14)
Voir la source
Indexation
-
Transient model of a refrigerant-to-water helic...
- Auteurs : NDIAYE D.
- Date : 05/02/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 112
Voir la fiche
-
The characteristics of flow patterns in the she...
- Auteurs : YANG Y., XU L., HAN H., REN Z., WU K., LIU F.
- Date : 08/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 152
- Formats : PDF
Voir la fiche
-
Modeling refrigerant maldistribution in microch...
- Auteurs : ZOU Y., TUO H., HRNJAK P. S.
- Date : 03/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 64 - n. 1-2
Voir la fiche
-
Modeling framework to predict two-phase flow di...
- Auteurs : MAHVI A. J., GARIMELLA S.
- Date : 08/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
Voir la fiche
-
Two-phase vertical downward flow in plate heat ...
- Auteurs : TAO X., NUIJTEN M. P., INFANTE FERREIRA C. A.
- Date : 01/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
Voir la fiche