Document IIF

Ventilation nocturne et refroidissement mécanique : calcul de la relation.

Calculation of nocturnal ventilation and its relation with mechanical cooling.

Auteurs : CAO S., LI Z.

Résumé

The paper summarizes the calculation method used for nocturnal ventilation and finds a solution concerning the major parameters such as airflow volume, ventilation period, indoor temperatures, etc. By testing a room in Shanghai, it verifies the reliability of the calculation method and finds that nocturnal ventilation can save energy only for areas where the temperature difference during the day is important.

Documents disponibles

Format PDF

Pages : 2000-3

Document à numériser, disponible sous dix jours

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Calculation of nocturnal ventilation and its relation with mechanical cooling.
  • Identifiant de la fiche : 2001-2876
  • Langues : Anglais
  • Source : International Symposium on Air Conditioning in High-Rise Buildings - 2000.