Vérification de la qualité de l'air intérieur avant et après installation d'un système préventif contre l'allergie dans une maison.
Verification of indoor air quality before and after moving in the house with the countermeasure against allergy.
Numéro : pap. 543
Auteurs : MITAMURA T., HARASAWA H., DOBASHI K.
Résumé
Allergy symptoms are intimately related to indoor air quality. It is said that PM2.5 would cause asthma and bronchitis. A whole house air-conditioning system integrated with an electrical dust collector was developed for the countermeasure against allergy. This air-cleaning system could remove fine particles such as PM2.5. The purpose of this study is to make clear the relationship between symptoms of allergy and indoor air quality. The concentrations of fine-particles and airborne fungi, as well as the amounts of mite allergens were measured before and after moving in the house which installed an air-cleaning system. The results showed that the concentrations of fine-particles and airborne fungi were lower than that of the houses before occupying. The amounts of mite allergens were also lower. Most of the residences said that the symptoms of allergy were improved after moving in the houses with the countermeasure against allergy.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Verification of indoor air quality before and after moving in the house with the countermeasure against allergy.
- Identifiant de la fiche : 30009343
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Qualité de l'air intérieur
- Mots-clés : Maison individuelle; Qualité de l'air; Particule; Enquête; Conditionnement d'air
-
Maison ou immeuble malsains et qualité de l'air...
- Auteurs : KAGI N.
- Date : 05/2010
- Langues : Japonais
- Source : Refrigeration - vol. 85 - n. 991
Voir la fiche
-
Ventilation in French buildings.
- Auteurs : DEROUBAIX P., LUCAS J. P., RAMALHO O., et al.
- Date : 09/2009
- Langues : Anglais
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 30 - n. 4
Voir la fiche
-
Qualité de l'air intérieur dans des maisons éta...
- Auteurs : YOKOYAMA S., TSUKIDATE T.
- Date : 10/1995
- Langues : Japonais
- Source : SHASE - vol. 69 - n. 10
Voir la fiche
-
Radon as an indoor air hazard.
- Auteurs : DUNSTER H. J.
- Date : 05/1992
- Langues : Anglais
- Source : Indoor Environ. - vol. 1 - n. 3
Voir la fiche
-
Improvement of indoor air quality in four probl...
- Auteurs : SHAW C. Y., SALARES V., MAGEE R. J., et al.
- Date : 01/1999
- Langues : Anglais
- Source : Build. Environ. - vol. 34 - n. 1
Voir la fiche