Analyse des paramètres d'un sous-système de régénération dans des systèmes de déshumidification à déshydratant liquide.

Analysis on parameters of regeneration subsystem in liquid desiccant dehumidification systems.

Numéro : pap. 2194

Auteurs : TU M., REN C. Q., CHENG H., et al.

Résumé

Along with the widely use in industries and lives, the dehumidification systems have consumed a large amount of energy. Fortunately, the application of liquid desiccant dehumidification system can greatly reduce the consumption of high-grade energy. To improve the advantages of liquid desiccant system compared with the conventional dehumidification system, one of the key measures is to increase the efficiency of the regeneration sub-system. In this study, models for the regeneration tower and counter-current heat exchanger, which are recognized by previous experiments, are employed and the corresponding VC++ computer program modules are used to describe the heat and mass transfer processes between the liquid desiccant solution and moist air in the regenerator and the heat transfer process in heat exchanger respectively. The orthogonal design is used to arrange the numerical experiment. The results are analyzed by the method of variance analysis to determine the relative significance of operating parameters and the interactions between them. The analysis on the influence factors shows that for the evaporation rate of water vapor in the regenerator, the important parameters are the inlet temperature and concentration of the solution, the mass flow ratio of dry air to dehydrated desiccant, and the NTU of the regenerator. The analysis also shows that for the regeneration efficiency, the important parameters are the mass flow ratio of dry air to dehydrated desiccant, the NTU of the regenerator and the inlet temperature of solution. There is no interaction that influences the evaporation rate of water vapor and the regeneration efficiency significantly.

Documents disponibles

Format PDF

Pages : 9 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Analysis on parameters of regeneration subsystem in liquid desiccant dehumidification systems.
  • Identifiant de la fiche : 30013310
  • Langues : Anglais
  • Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 14/07/2014

Liens


Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence