Document IIF
Amélioration de la performance d'un système de conditionnement d'air au CO2 muni d'un éjecteur commandé.
Performance enhancement of CO2 air conditioner with a controllable ejector.
Auteurs : LIU F., LI Y., GROLL E. A.
Type d'article : Article, Article de la RIF
Résumé
This study presents performance enhancement of a transcritical CO2 air conditioner with a controllable ejector at variable operating conditions and variable compressor frequencies. The effects of ejector geometries, operating conditions and compressor frequency on the performance of an ejector expansion transcritical CO2 air conditioner were investigated. Experimental results show that the COP of a CO2 air conditioning system can be enhanced by using an ejector expansion device to replace a conventional expansion valve. This enhancement became more significant as the outdoor air temperature increased (COP increased by up to 36%), the compressor frequency decreased (COP increased by up to 147% compared to conventional cycle with compressor frequency at 50 Hz), and the motive nozzle throat diameter decreased (COP increased by up to 60%). In addition, the COP reached a maximum when the distance between motive nozzle exit and mixing section entrance was three times the mixing section diameter.
Documents disponibles
Format PDF
Pages : 1604-1616
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance enhancement of CO2 air conditioner with a controllable ejector.
- Identifiant de la fiche : 30004801
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 6
- Date d'édition : 09/2012
Liens
Voir d'autres articles du même numéro (28)
Voir la source
Indexation
-
Integration of a two-phase ejector into a compa...
- Auteurs : ELBEL S., REICHLE M., BOWERS C., et al.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Étude expérimentale sur la performance du cycle...
- Auteurs : LI Q., GUO X., LI W., et al.
- Date : 10/2012
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 33 - n. 147
- Formats : PDF
Voir la fiche
-
A non symmetric interfacial area density formul...
- Auteurs : ORTEGO SAMPEDRO E.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Analysis of the R744 flow through the ejector d...
- Auteurs : BODYS J., PALACZ M., HAIDA M., SMOLKA J., NOWAK A. J.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
Performance evaluation of CO2 ejecto...
- Auteurs : SINGH S., BANASIAK K., HAFNER A., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche