Document IIF
Amélioration de la performance d'une pompe à chaleur à l'aide d'un écoulement du frigorigène pulsé et d'un robinet solénoïde de régulation.
Enhancement of heat pump performance by pulsation of refrigerant flow using a solenoid-driven control valve.
Résumé
The heating performance of an R410A heat pump system can be enhanced by a pulsatile refrigerant flow in a heat pump cycle. To generate the pulsatile refrigerant flow, a control valve was installed in parallel with the expansion valve located between the outlet of the condenser and the inlet of the evaporator in this system. Intermittent 200-ms openings of the control valve improved the heating performance because of two factors: the ‘pulsation effect’ that enhanced heat transfer and the ‘pushing effect’ that elevated the condensing pressure and increased overall mass flow rate. Heating capacity and COP (coefficient of performance) were increased by 4 and 3.2%, respectively, when the control valve operated at 0.005 Hz and 0.1% duty. In phenomenological view, two-phase invasion is considered when the control valve is operated.
Documents disponibles
Format PDF
Pages : 1547-1557
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Enhancement of heat pump performance by pulsation of refrigerant flow using a solenoid-driven control valve.
- Identifiant de la fiche : 30004795
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 6
- Date d'édition : 09/2012
Liens
Voir d'autres articles du même numéro (28)
Voir la source
Indexation
-
CONTROLE AUTOMATIQUE DU FONCTIONNEMENT DE ROBIN...
- Auteurs : GORBUNOV S. I., MAJOROV V. V.
- Date : 1984
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 4
Voir la fiche
-
CONTROL VALVES FOR INDUSTRIAL REFRIGERATION.
- Auteurs : STRONG A. P.
- Date : 04/1988
- Langues : Anglais
- Source : Heat. Pip. Air Cond. - vol. 60 - n. 4
Voir la fiche
-
Diagnosing and curing a sick solenoid valve.
- Auteurs : GAMMON R., TIEGS T.
- Date : 06/03/2000
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News - vol. 209 - n. 10
Voir la fiche
-
Vannes solénoïdes et vannes motorisées.
- Auteurs : KATO T.
- Date : 09/1993
- Langues : Japonais
- Source : Refrigeration - vol. 68 - n. 791
Voir la fiche
-
Etude théorique concernant l'influence des impu...
- Auteurs : SEMENÛK Û. V., ANTCHERBAK S. N., ZELEZNYJ V. P., et al.
- Date : 2006
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 10
Voir la fiche