Résumé
Due to its low environmental impact, the use of transcritical R744 systems has become increasingly popular in recent years in a variety of different applications. For applications that span a wide temperature range between the heat source and heat sink, the use of two-stage compressor results in numerous advantages in terms of efficiency and compressor discharge temperature. This paper presents experimental data for a transcritical R744 compressor system operating at high heat rejection temperatures. A comprehensive system model was developed and validated with the experimental results. Based on this, the simulation tool was used to further optimize the system design specifically to accommodate the two-stage compression process. The optimum heat transfer area distribution has been determined to simultaneously ensure efficient intercooling at intermediate pressure and gas cooling at the high-pressure level. Simultaneously, the system was also optimized with respect to optimal intermediate pressure and the results show that for this particular system, the optimum intercooler pressure deviated substantially from the standard design approach that uses the geometric mean between suction and discharge pressures.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Improvement of capacity and COP through use of two-stage compressor in transcritical R744 systems.
- Identifiant de la fiche : 30027657
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : IIR Rankine Conference 2020.
- Date d'édition : 31/07/2020
- DOI : http://dx.doi.org/10.18462/iir.rankine.2020.1133
Liens
Voir d'autres communications du même compte rendu (75)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Compresseurs - Mots-clés : Système biétage; Compresseur; CO2; R744; Cycle transcritique; COP; Optimisation; Transfert de chaleur; Simulation
-
Experimental investigation on a two-stage trans...
- Auteurs : CASSON V., CAVALLINI A., CECCHINATO L., et al.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
On the optimum interstage parameters for CO2 tr...
- Auteurs : MANOLE D.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Shape optimization and fluid control of near is...
- Auteurs : LIU H., AUTE V., HWANG Y., LEE C., MUEHLBAUER J., GAO L.
- Date : 08/2024
- Langues : Anglais
- Source : 16th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2024). Proceedings. University of Maryland, College Park, Maryland, USA, August 11-14 2024
- Formats : PDF
Voir la fiche
-
Optimization of two-stages CO2 transcritical cy...
- Auteurs : TRABUCCHI S., ORLANDI M.
- Date : 11/04/2019
- Langues : Anglais
- Source : 8th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, Avril 11-13, 2019.
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis of different two-stage t...
- Auteurs : CECCHINATO L., CORRADI M., FORNASIERI E., et al.
- Date : 02/08/2005
- Langues : Anglais
- Source : Commercial Refrigeration. Thermophysical Properties and Transfer Processes of Refrigerants. Proceedings of the IIR International Conferences.
- Formats : PDF
Voir la fiche