Document IIF

Ammoniac dans la réfrigération et les systèmes de pompe à chaleur de faible puissance.

Ammonia in small-capacity refrigeration and heat-pump systems.

Auteurs : PALM B.

Résumé

Ammonia has been used as refrigerant in large systems continuously since the beginning of the era of refrigeration. In small systems, it has hardly been used at all since the introduction of the halogenated hydrocarbons around 1930. Lately, with the search for alternatives with less influence on global warming, the use of ammonia in small systems has come into focus again. In this paper, we will describe the work done at the Royal Institute of Technology with the aim of developing a prototype of a domestic water to water heat pump with a heating capacity of around 6 kW. It has been shown that such a system can be designed to operate with less than 100 g of ammonia. The main obstacle for introducing this technology commercially is the lack of components. Particularly, there seem to be no hermetic or semi-hermetic compressors available in this size range.

Documents disponibles

Format PDF

Pages : ICR07-B2-1103

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Ammonia in small-capacity refrigeration and heat-pump systems.
  • Identifiant de la fiche : 2007-1923
  • Langues : Anglais
  • Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Date d'édition : 21/08/2007

Liens


Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence