Analyse computationnelle d’un éjecteur avec tuyère oscillante.

Computational analysis of ejector with oscillating nozzle.

Numéro : pap. 2326

Auteurs : ARUN K. M., TIWARI S., MANI A.

Résumé

Present study numerically investigates the effect of oscillation of convergent-divergent nozzle in an ejector using ANSYS Fluent.15.5. The nozzle domain will oscillate between two points in the ejector at particular frequency and amplitude. The motion of nozzle and movement of the mesh according to the nozzle oscillation is made possible by user-defined functions available in ANSYS Fluent 15.5. Variation of entrainment ratio with time has been studied at different amplitudes and frequency combination and the same is compared with the stationary nozzle. Even though the oscillating nozzle underperforms the conventional one at lower amplitude and frequency, the former one shows a trend of increasing with increasing frequency.

Documents disponibles

Format PDF

Pages : 9

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Computational analysis of ejector with oscillating nozzle.
  • Identifiant de la fiche : 30024498
  • Langues : Anglais
  • Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 09/07/2018

Liens


Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence