Résumé
Based on a building located in Beijing, the influence of the meteorological parameter, indoor design temperature, the building facade and its effective thermal insulation on the air-conditioning load is researched. Results show that: 1) the influence of outdoor design temperature on the cooling load is significant. The cooling load will increase 5~6% as the outdoor design temperature increase 1°C; 2) the exterior wall or windows of the building toward west must be reduced; 3) when thermal conductivity of the exterior wall varies from 0.54 to 2W/(m2K), the cooling and heating load of the building will increase 4.7 and 38%, respectively; 4) when thermal conductivity of the exterior windows changes from .3 to 6.4 W/(m2K), the cooling and heating load of the building will increase 7.8 and 47.1%, respectively. Therefore, a reasonable selection of outdoor temperature and materials of building envelope can significantly reduce the air-conditioning load.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis on the air-conditioning load in cold regions.
- Identifiant de la fiche : 30002910
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Bilan thermique; Chine; Immeuble; Météorologie; Conditionnement d'air; Charge frigorifique; Climat froid
-
Atrium buildings: thermal performance and clima...
- Auteurs : ATIF M. R., CLARIDGE D. E., BOYER L. L., DEGELMAN L. O.
- Date : 01/1995
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
A SIMPLIFIED METHOD OF ENERGY CONSUMPTION ESTIM...
- Auteurs : LIN H. T., YANG K. H.
- Date : 03/09/1987
- Langues : Anglais
Voir la fiche
-
THE RESEARCHES ON AIR CONDITIONING LOAD CALCULA...
- Auteurs : JIPING S.
- Date : 16/05/1984
- Langues : Anglais
Voir la fiche
-
Field study of occupant comfort and office ther...
- Auteurs : DONNINI G., MOLINA J., MARTELLO C., LAI D. H. C., LAI H. K., CHANG C. Y., LAFLAMME M., NGUYEN V. H., HAGHIGHAT F.
- Date : 1997
- Langues : Anglais
- Source : ASHRAE Transactions.1997 Annual Meeting, Boston, MA.
Voir la fiche
-
Outdoor thermal comfort study in northern China.
- Auteurs : LAI D., LIN C., CHEN Q.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche