Document IIF
Analyse de la distribution de l'écoulement d'air dans les systèmes frigorifiques.
Analysis of air flow distribution in refrigeration systems.
Auteurs : BRIX W., JAKOBSEN A., RASMUSSEN B. D., et al.
Résumé
A simulation model with heat transfer and pressure drop properties based on existing correlations was built to investigate the influence of unevenly distributed air flows on a microchannel evaporator. On the refrigerant side liquid overfeed is used in the evaporator and on the air side only dry air is considered to flow through the evaporator. The simulation model was used to analyze the capacity degradation caused by the airflow nonuniformity. It was found that the cooling capacity of the heat exchanger was decreased by 20% for extreme maldistributions of the airflow. However, for not so severe airflow maldistributions, the degradation of the overall heat transfer coefficient was limited. Finally, the evaporator model was built into a relatively simple refrigeration system model in order to analyse influence of the airflow maldistribution on the total system performance. It was found that the degradation of the COP was only 4% in the extreme case and negligible for all air flow distributions that were not severely non-uniform.
Documents disponibles
Format PDF
Pages : ICR07-B2-581
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis of air flow distribution in refrigeration systems.
- Identifiant de la fiche : 2008-0141
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
-
A numerical study of minichannel and microchann...
- Auteurs : GOSSARD J. J., HAN X., RAMALINGAM M., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
A generalized effectiveness-NTU based variable ...
- Auteurs : HUANG L., AUTE V., RADERMACHER R.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental analysis of peripheral finned-tube...
- Auteurs : PUSSOLI B. F., BARBOSA J. R. Jr, SILVA L. W. da, et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
A mass flow based generalized microchannel heat...
- Auteurs : HUANG L., AUTE V., RADERMACHER R.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Study on the numerical modeling of convective h...
- Auteurs : LEE G., CHOI J., JOUNG T., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche