Document IIF
Analyse de la performance de meubles frigorifiques de vente utilisant le R-404A et le R-22 comme frigorigène.
Performance analysis of refrigerated display cabinets with R-404A and R-22 refrigerants.
Auteurs : GE Y., TASSOU S. A.
Résumé
Refrigerant R-404A is being employed in modern supermarkets as a replacement of R-22 because of its zero global warming potential. A modern supermarket contains a large number of display cabinets to store and display chilled and frozen food products. These display cabinets are invariably located remotely and served by central multi-compressor refrigeration systems. This paper simulates and compares the performance of R-22 and R-404A refrigerants in medium temperature refrigerated display cabinets for supermarket applications. The model of display cabinet is based on three sub-models, the air-cooling finned-tube evaporator, the air curtain and the display cabinet body. The evaporator coil is modelled using the distributed method which allows the investigation of alternative geometries. The air curtain is modelled using correlations developed from detailed finite difference models. Results indicate that a cabinet operating with R-404A for the same operating conditions will have higher cooling load and higher refrigerant flow rate than as cabinet with R-22. The model can be used to evaluate other refrigerants and optimize the performance of the evaporator coil. The model will also be used in an integrated supermarket refrigeration and environmental control system mode.
Documents disponibles
Format PDF
Pages : ICR07-B2-1112
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance analysis of refrigerated display cabinets with R-404A and R-22 refrigerants.
- Identifiant de la fiche : 2008-0681
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HCFC;
Supermarchés, meubles de vente;
Mélanges - Mots-clés : Meuble de vente; R404A; R22; Supermarché; Simulation; Performance; Modélisation; Frigorigène
-
The configuration coefficient as quality criter...
- Auteurs : MEFFERT H. F. T.
- Date : 1999
- Langues : Anglais
- Source : Refrigerated Transport, Storage and Retail Display.
- Formats : PDF
Voir la fiche
-
Supermarket demand response using the CO2 boost...
- Auteurs : BUSH J., LING J., AUTE V., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Improvement of temperature uniformity in open r...
- Auteurs : LIN H. W., CHEN Y. F., HSIEH W. D., et al.
- Date : 20/05/2009
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
Voir la fiche
-
A theoretical and experimental analysis of a se...
- Auteurs : RONZONI A. F., HEINZLE G., FURLAN A. A., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
A comparative study of the effect of initial tu...
- Auteurs : CHEN Y. F., LIN H. W., HSIEH W. D., et al.
- Date : 21/06/2009
- Langues : Anglais
- Source : 2009 ASHRAE Annual Conference CD. Transactions papers presented at the 2009 ASHRAE Annual Conference: Louisville, KY, June 2009. Volume 115, part 2.
Voir la fiche