ANALYSE DE LA PERFORMANCE THERMIQUE D'ECHANGEURS DE CHALEUR A TUBES A AILETTES, A BASSES TEMPERATURES ET A FAIBLES DEBITS D'AIR.

THERMAL PERFORMANCE ANALYSIS OF FINNED TUBE HEAT EXCHANGERS AT LOW TEMPERATURES AND AIRFLOW RATES.

Résumé

DANS CE RAPPORT, ON EXAMINE LES CARACTERISTIQUES DE PERFORMANCE THERMIQUE D'UN ECHANGEUR DE CHALEUR A TUBES A AILETTES, DU TYPE COURAMMENT UTILISE EN TANT QU'EVAPORATEUR DANS DES REFRIGERATEURS DOMESTIQUES. ON A MIS AU POINT UNE INSTALLATION D'ESSAI A BASSES TEMPERATURES AFIN DE REPRESENTER LES CONDITIONS DE FONCTIONNEMENT REELLES DE L'APPLICATION DU REFRIGERATEUR. POUR CETTE PREMIERE ETAPE D'ESSAI, ON A UTILISE UN LIQUIDE A UNE PHASE SUR LE COTE DU TUBE DE L'ECHANGEUR DE CHALEUR. ON A ANALYSE LES EFFETS DE LA GEOMETRIE DES TUBES, DE L'ESPACEMENT DES AILETTES ET DE LEUR EPAISSEUR SUR LA PERFORMANCE DE L'ECHANGEUR DE CHALEUR. ON A EFFECTUE DES ESSAIS SUPPLEMENTAIRES AU COURS DESQUELS ON A EVALUE LA RESISTANCE AU CONTACT TUBE/AILETTE.

Détails

  • Titre original : THERMAL PERFORMANCE ANALYSIS OF FINNED TUBE HEAT EXCHANGERS AT LOW TEMPERATURES AND AIRFLOW RATES.
  • Identifiant de la fiche : 1989-2190
  • Langues : Anglais
  • Date d'édition : 1988
  • Source : Source : ASHRAE Trans.
    vol. 94; n. 2; 244-260; 11 fig.; 5 tabl.; 8 ref.; discuss.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.