Analyse de la performance thermique d’échangeurs de chaleur pour des unités de poutre froide actives.
Analysis of the thermal performance of heat exchangers for active chilled beam units.
Numéro : pap. 1158
Auteurs : DOMÍNGUEZ MUÑOZ F., GONZÁLEZ ESPÍN J. L., CORONAS A., et al.
Résumé
Coils used in active chilled beams (ACB) have some distinctive features compared to conventional coils used in fan-coil units. On the air side, the flow rate of induced air is limited and air velocities are thus much lower than those prevailing in fan-coils. Consequently, most of the correlations available in the open literature to calculate the convection coefficient on the air side are out of range when applied to ACB coils. In addition, the nature of the induction process causes some degree of non-uniformity in the air distribution over the coil. On the liquid side, circuitry can also be distinctive due to space constrains or functional requirements. Some commercial products use one circuit arrangements (all tubes connected in series) with different possible flow paths; two or more circuit schemes are also frequent. In this paper, ongoing research on active chilled beam modeling is presented. A generic numerical model of plate fin-and-tube heat exchanger is briefly described along with a test bench in which several ACB units have been tested. Experimental data for an example coil is used along with the coil model to determine a correlation for the air-side heat transfer. The calibrated numerical model is then used to simulate the coil.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis of the thermal performance of heat exchangers for active chilled beam units.
- Identifiant de la fiche : 30024128
- Langues : Anglais
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Date d'édition : 19/06/2018
Liens
Voir d'autres communications du même compte rendu (81)
Voir le compte rendu de la conférence
Indexation
-
Measuring and modelling heat exchange capacity ...
- Auteurs : DE CLERCQ B., DELTOUR B., VAN OVERLOOP J.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Detecting cooling coil fouling automatically. 1...
- Auteurs : VERONICA D. A.
- Date : 07/2010
- Langues : Anglais
- Source : HVAC&R Research - vol. 16 - n. 4
Voir la fiche
-
Structural and numerical identifiability of the...
- Auteurs : DOMÍNGUEZ MUÑOZ F., RUIVO C. R., CEJUDO LÓPEZ J. M., et al.
- Date : 19/06/2018
- Langues : Anglais
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche
-
Evaporator optimization for non-uniform air dis...
- Auteurs : DOMANSKI P. A., YASHAR D. A., LEE S.
- Date : 13/06/2010
- Langues : Anglais
- Source : IIR/Eurotherm sustainable refrigeration and heat pump technology conference. Proceedings of the Eurotherm Seminar No. 88, Stockholm, Sweden, June 13-16, 2010.
- Formats : PDF
Voir la fiche
-
Comparison of fin-and-tube interlaced and face ...
- Auteurs : KAERN M. R., ELMEGAARD B., LARSEN L. F. S.
- Date : 01/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
Voir la fiche