Document IIF
Analyse des performances d'un refroidisseur thermoélectrique pulsé à quatre étages pour détecteurs infrarouges à plan focal.
Performance analysis of four-stage thermoelectric cooler for focal plane infrared detectors.
Résumé
A cooler provides a low-temperature working environment for refrigerated infrared detection chips and is an indispensable component in infrared detectors that ensures their smooth operation. In this paper, a thermodynamic model of a heat-pipe-type four-stage thermoelectric cooler with a large temperature difference applied to a focal plane infrared detector is constructed. The heat leakage of the detector is calculated using the model. The performance indexes of the coordination performance coefficient and module utilization coefficient are used to unify the cooling capacity and economic performance of the device. The impression of the working current, heat pipe parameters, and cross-sectional area of the thermoelectric leg on the performance of cooler are analyzed. A Pareto optimal solution is obtained using an NSGA-II algorithm and TOPSIS decision. A low cooling temperature is obtained using a multistage thermoelectric cooler to achieve a large cooling temperature difference. When the working current is 5.65 A and the cross-sectional area is 4.5 mm2, the maximum cooling temperature difference reaches 110.6 °C, and the lowest cooling temperature reaches -83.6 °C. When the working temperature of the detector is -60 °C, the current and cross-sectional area corresponding to the optimal solution of cooling capacity-COP-power consumption are 1.51 A and 2.74 mm2, respectively.
Documents disponibles
Format PDF
Pages : 290-302
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance analysis of four-stage thermoelectric cooler for focal plane infrared detectors.
- Identifiant de la fiche : 30032476
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 165
- Date d'édition : 09/2024
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2024.06.011
Liens
Voir d'autres articles du même numéro (39)
Voir la source
Indexation
-
Analysis and optimization of air coolers using ...
- Auteurs : PROVENSI A., BARBOSA J. R. Jr
- Date : 02/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 110
- Formats : PDF
Voir la fiche
-
Numerical simulations and optimized design on t...
- Auteurs : ZHANG J., ZHAO H., FENG B., SONG X., ZHANG X., ZHANG R.
- Date : 02/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 146
- Formats : PDF
Voir la fiche
-
Ansys et recherche expérimentale sur un refroid...
- Auteurs : ZHAO J., ZHU H., QIU H.
- Date : 02/2015
- Langues : Chinois
- Source : Refrigeration - vol. 34 - n. 2
Voir la fiche
-
Thermodynamical analysis of thermoelectrical mu...
- Auteurs : WARTANOWICZ T.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Traveling-wave thermoacoustic refrigerator for ...
- Auteurs : WAN X., WU Z., ZHANG L., HU J., LUO E.
- Date : 12/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 120
- Formats : PDF
Voir la fiche