In this study, a one dimensional, time dependent model is used to study the performance of a magnetic refrigeration system. The objective is to quantify system losses and identify the operating conditions that maximize the performance. Parameters related to configuration such as external heat leaks and demagnetization effects are included. A simple resistance network model is used to simulate external losses. Through experiments, loss coefficient factors are estimated to determine conductance linking the cold side of the system to the environment and to the hot side. It is found experimental results on AMRs may underestimate intrinsic regenerator performance if losses are not considered. A detailed numerical study is performed to investigate the impacts of operating temperature on the performance of the system. Results indicate that the system efficiency is maximized when the average temperature of the matrix is slightly higher than the Curie point of the refrigerant.
Documents disponibles
Format PDF
Pages : 4 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance analysis of an active magnetic refrigeration system with external loss mechanisms.
- Identifiant de la fiche : 30019280
- Langues : Anglais
- Source : 7th International Conference on Magnetic Refrigeration at Room Temperature (Thermag VII). Proceedings: Turin, Italy, September 11-14, 2016.
- Date d'édition : 11/09/2016
- DOI : http://dx.doi.org/10.18462/iir.thermag.2016.0076
Liens
Voir d'autres communications du même compte rendu (71)
Voir le compte rendu de la conférence
-
Dynamic operation of an active magnetic regener...
- Auteurs : TUSEK J., KITANOVSKI A., PREBIL I., et al.
- Date : 09/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 6
- Formats : PDF
Voir la fiche
-
The operating principle of a fully solid state ...
- Auteurs : ZHANG M., MEHDIZADEH MOMEN A., ABDELAZIZ O.
- Date : 11/09/2016
- Langues : Anglais
- Source : 7th International Conference on Magnetic Refrigeration at Room Temperature (Thermag VII). Proceedings: Turin, Italy, September 11-14, 2016.
- Formats : PDF
Voir la fiche
-
Performance evaluation of an active magnetic re...
- Auteurs : TREVIZOLI P. V., NAKASHIMA A. T., BARBOSA J. R. Jr
- Date : 12/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 72
- Formats : PDF
Voir la fiche
-
Plage de température de fonctionnement d’un réf...
- Auteurs : OKAMURA T., ARITA S., OKUBO T., et al.
- Date : 03/2016
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 33 - n. 3
Voir la fiche
-
Giant magnetocaloric effect of compressible Isi...
- Auteurs : AMARAL J. S., FORTUNATO N. M., AMORIM C. O., et al.
- Date : 11/09/2016
- Langues : Anglais
- Source : 7th International Conference on Magnetic Refrigeration at Room Temperature (Thermag VII). Proceedings: Turin, Italy, September 11-14, 2016.
- Formats : PDF
Voir la fiche