Document IIF
Analyse des performances d'une nouvelle pompe à chaleur aérothermique en cascade ammoniac/eau pour le chauffage de bâtiments dans un climat subarctique.
Performance analysis of a novel air source ammonia/water cascade heat pump for heating buildings in subarctic climate.
Auteurs : HOSSEINNIA S. M., AMIRI L., PONCET S.
Type d'article : Article de la RIF
Résumé
Performance of available air-source heat pumps (ASHP) for buildings is extremely influenced by the outdoor air temperature (OAT). When OAT falls below –20 °C, especially in subarctic climate, most commercially available ASHPs lose their defined functionality. To address this issue, a novel cascade heat pump (CHP) is proposed that utilizes two natural (with zero global warming index) refrigerants: ammonia, aka R717, as the low stage (LS) refrigerant, and water, aka R718, as the high stage (HS) working fluid. The proposed system is equipped with two rotary vane compressors for LS and HS. To desuperheat the compressor discharge temperatures and increase the HS heating capacity, liquid refrigerant is injected into the chamber of both LS and HS compressors. The wet compression is thermodynamically modeled and validated against experimental data available in the literature. Optimum design parameters such as the maximum allowable temperatures during compression and the minimum vapor quality after injection are obtained where the COP is maximized. Total exergy destruction, number/location of injectors and the injected amounts are also investigated. The proposed CHP can deliver 6.35 kW heating load at 50 °C with a COP of 1.985 when OAT is –40 °C. From a broader perspective, the proposed CHP not only proves its efficacy in extremely cold subarctic climates but also emerges as a pivotal player in addressing the global warming issue. This is accomplished through a dual approach to decarbonization—firstly, by electrifying heating processes and secondly, by substituting phased-out refrigerants with environmentally friendly natural alternatives.
Documents disponibles
Format PDF
Pages : 57-74
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance analysis of a novel air source ammonia/water cascade heat pump for heating buildings in subarctic climate.
- Identifiant de la fiche : 30032403
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 164
- Date d'édition : 08/2024
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2024.04.026
Liens
Voir d'autres articles du même numéro (20)
Voir la source
Indexation
-
Experimental study of a control strategy for a ...
- Auteurs : QU M., FAN Y., LI T., et al.
- Date : 05/01/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 110
Voir la fiche
-
High temperature industrial heat pumps utilisin...
- Auteurs : NEKSÅ P., BANTLE M., SCHLEMMINGER C., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Feasibility study of various conventional and u...
- Auteurs : YOUNG J., SUBIANTORO A.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
A cascade heat pump for water heating.
- Auteurs : CLELAND D. J., CAVILL J. P., JOHNSON D.
- Date : 07/04/2016
- Langues : Anglais
- Source : 4th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Auckland, New Zealand, April 7-9, 2016.
- Formats : PDF
Voir la fiche
-
Experimental study on the performance of R290 a...
- Auteurs : LEI B., SHI H., WANG C., WU J., ZHANG L.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche