Analyse des performances et optimisation d’un nouveau refroidisseur double effet à absorption de bromure de lithium-eau avec des écoulements en série et en parallèle.

Performance analysis and optimization of new double effect lithium bromide–water absorption chiller with series and parallel flows.

Auteurs : CHAHARTAGHI M., GOLMOHAMMADI H., SHOJAEI A. F.

Type d'article : Article, Article de la RIF

Résumé

In this paper the effect of some key parameters on coefficient of performance (COP) in two novel arrangements of double effect lithium bromide–water absorption chillers with series and parallel flow have been studied. The main components of these cycles are generators, absorber, condensers, evaporator and heat exchangers. The mass, concentration, and energy balance equations are used for both cycles and performances of the systems are analyzed at different conditions with the condition of no formation of lithium bromide crystal. Also, the effects of temperatures and mass flow rates of inlet vapor of generator and inlet water of absorber on evaporator cooling capacity, absorber heat transfer rate and COP are investigated. In addition, two new parameters based on mass ratio of solution splitters are defined (R1 and R2) and their effects on the system performance are analyzed. The results show that the series cycle at inlet vapor temperature to the high temperature generator (HTG) below 150 °C has higher COP than the parallel cycle. In addition, with increase of inlet vapor temperature to HTG and rise of mass flow rate of inlet water to absorber, the COP increases in both parallel and series cycles. In addition, with increase of R1, the COP increases at first and reaches to a maximum value, and then decreases. Furthermore, the Genetic Algorithm (GA) method has been used to optimization of the system COP at series and parallel cycles.

Documents disponibles

Format PDF

Pages : 73-87

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Performance analysis and optimization of new double effect lithium bromide–water absorption chiller with series and parallel flows.
  • Identifiant de la fiche : 30025349
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 97
  • Date d'édition : 01/2019
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.08.011

Liens


Voir d'autres articles du même numéro (18)
Voir la source