Document IIF
Analyse des pertes dans un moteur synchrone à aimant permanent utilisé pour faire fonctionner le compresseur d'un système de conditionnement d'air.
Analysis of the losses in a permanent magnet synchronous motor used to drive the compressor in an air-conditioning system.
Résumé
In an air-condition system, most of the electricity is consumed in operating the compressor. Therefore, developing a high efficiency compressor is necessary to increase the energy efficiency. To increase the efficiency of the PM motor, it is important to reduce the losses. The operating frequency of permanent magnet synchronous motor (PMSM) varies frequently, and so do its losses. In this paper, losses of motor at different frequencies were tested, and the experimental results were compared with the results of the engineering calculation. At last, the authors investigated the main factors which affect losses, and some guidelines for the reference design of the motor were drawn.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis of the losses in a permanent magnet synchronous motor used to drive the compressor in an air-conditioning system.
- Identifiant de la fiche : 30002959
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Conditionnement d'air : généralités;
Compresseurs;
Evaporateurs, condenseurs et autres échangeurs thermiques;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité - Mots-clés : Calcul; Aimant; Rendement; Recommandation; Perte; Moteur électrique; Conditionnement d'air; Compresseur
-
Starting performance analysis of single-phase l...
- Auteurs : HU Y., ZHANG F., ZHANG X.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Cost-optimal design for cooling towers.
- Auteurs : KINTNER-MEYER M., EMERY A. F.
- Date : 04/1995
- Langues : Anglais
- Source : ASHRAE Journal - vol. 37 - n. 4
Voir la fiche
-
Régulateurs de vitesse électroniques ajustables...
- Auteurs : MENNINK D. B. D.
- Date : 12/1992
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 85 - n. 12
Voir la fiche
-
CAPACITY CONTROL OF A REFRIGERATION SYSTEM USIN...
- Auteurs : WONG A. K. H., JAMES R. W.
- Date : 1988
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 9 - n. 2
Voir la fiche
-
Diagnostic du fonctionnement des condenseurs à ...
- Auteurs : BABAKIN B. S., VYGODIN V. A., KULAGIN V. N., et al.
- Date : 2000
- Langues : Russe
Voir la fiche