Document IIF
Analyse énergétique et exergétique d'un nouveau cycle frigorifique à éjecteur biétagé utilisant des mélanges zéotropiques binaires
Energy and exergy analysis of a novel two-stage ejector refrigeration cycle using binary zeotropic mixtures.
Résumé
To improve the ejector refrigeration cycle performance, this paper presents a theoretical thermodynamic analysis of a novel two-stage ejector refrigeration cycle (TSERC) with a gas-liquid separator using R134a/R32 and R600a/R290 as refrigerant. By separating the relatively low-boiling-point and high-boiling-point refrigerants, the cycle compression ratio decreases, the cycle performance increases, and the energy utilization efficiency can be improved. Energy and exergy analysis were conducted for the traditional single-stage ejector refrigeration cycle (SSERC) and TSERC. The effect of the mixture mass fraction on cycle performance under a fixed external heat source operating condition was studied, and the cycle performance comparisons between TSERC and SSERC at different evaporation temperature, condensation temperature and generation temperature were conducted. Results show that for TSERC, the maximum COP values 0.126 and 0.11, the maximum exergy efficiency 4.51 % and 4 % are obtained as the low-boiling-point mass fraction equals 0.6 and 0.4 respectively for R134a/R32 and R600a/R290. It is found that exergy destruction mainly occurs in the low-pressure sub-cycle of TSERC, the top three largest exergy destruction components are ejector 1, condenser 1 and generator 1, while the smallest exergy destruction occurs in pump 2. In addition, cycle performance comparison between SSERC and TSERC shows that the maximum COP improvement increased by 41.6 % and 89.6 % for 134a/R32 and R600a/R290 for TSERC, while the maximum entrainment ratio improvement increased by 32.4 % and 87.6 %. Moreover, it is concluded that the cycle performance improvement of TSERC is more significant at lower evaporation temperature, higher condensation temperature, and lower generation temperature compared to SSERC.
Documents disponibles
Format PDF
Pages : 178-189
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy and exergy analysis of a novel two-stage ejector refrigeration cycle using binary zeotropic mixtures.
- Identifiant de la fiche : 30032852
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 168
- Date d'édition : 12/2024
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2024.08.016
Liens
Voir d'autres articles du même numéro (63)
Voir la source
Indexation
-
The behaviour of a hybrid compressor and ejecto...
- Auteurs : HERNÁNDEZ J. I., DORANTES R. J., BEST R., et al.
- Date : 09/2004
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 24 - n. 13
Voir la fiche
-
Performance analysis and optimization of a new ...
- Auteurs : YARI M.
- Date : 10/2009
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 48 - n. 10
Voir la fiche
-
The effect of fractionation inside the storage ...
- Auteurs : HAIDER M.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis of performance of liquid...
- Auteurs : PAWLUCZUK A., BUTRYMOWICZ D., SMIERCIEW K., et al.
- Date : 06/09/2017
- Langues : Anglais
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche
-
Thermodynamic comparison of ejector cooling cyc...
- Auteurs : EXPÓSITO CARRILLO J. A., SÁNCHEZ DE LA FLOR F. J., SALMERÓN LISSEN J. M.
- Date : 02/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Formats : PDF
Voir la fiche