Analyse exergétique d’un système frigorifique à absorption de vapeur utilisant le dioxyde de carbone comme frigorigène.
Exergy analysis of a vapor absorption refrigeration system using carbon dioxide as refrigerant.
Numéro : pap. 2131
Auteurs : GAUTAM S., ROY A., AGGARWAL B.
Résumé
Vapor absorption refrigeration systems can replace vapor compression systems in many applications as they can operate on a low-grade heat source and are environment friendly. Widely used refrigerants such as CFCs and HFCs cause significant global warming. Natural refrigerants can be an alternative to them, among which carbon dioxide is promising. Its inherent safety, ability to withstand high pressure and high heat transfer coefficient coupled with easy availability make it a likely choice for refrigerant. [Bmim][PF6] is a room temperature ionic liquid (RTIL) composed of a large organic cation and an inorganic anion. Its properties such as non-toxicity, stability over a wide temperature range and ability to dissolve gases like carbon dioxide, make it a suitable absorbent for a vapor absorption refrigeration system. In this paper, an absorption chiller utilising the CO2-[bmim][PF6] working pair and consisting of a generator, condenser, evaporator and absorber has been proposed. A thermodynamic model was set up using the Redlich-Kwong cubic equations of state to predict the behavior of the refrigerant and absorbent pair at different points in the system. A MATLAB code was used to obtain the values of enthalpy and entropy at selected points in the system. The exergy destruction in each component and exergetic coefficient of performance (ECOP) of the system were calculated by performing an exergy analysis based on the second law of thermodynamics. The effect of every component on the ECOP was examined by calculating the amount of energy destructions in each of them. The exergetic coefficient of performance was calculated for five generator temperatures in the range of 60-100ºC for an evaporator temperature of 10ºC and was found to be in the range of 0.02-0.2. Such a chiller can be employed for refrigeration purposes, such as in the storage of food items.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Exergy analysis of a vapor absorption refrigeration system using carbon dioxide as refrigerant.
- Identifiant de la fiche : 30024412
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Mesures thermodynamiques;
CO2;
Systèmes à absorption et adsorption - Mots-clés : Thermodynamique; Exergie; Vapeur; R744; Système à absorption; Modélisation; Enthalpie; COP; CO2
-
Investigating the performance of novel green so...
- Auteurs : HAGHBAKHSH R., PEYROVEDIN H., RAEISSI S., DUARTE A. R. C., SHARIATI A.
- Date : 05/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 113
- Formats : PDF
Voir la fiche
-
Measurement of thermodynamic properties of ammo...
- Auteurs : SHARMA R., ANIL KUMAR E.
- Date : 07/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 67
- Formats : PDF
Voir la fiche
-
EVALUATION OF THERMODYNAMIC PROPERTIES OF BINAR...
- Auteurs : BORDE I., JELINEK M.
- Date : 1987
- Langues : Anglais
Voir la fiche
-
EXERGY ANALYSIS OF AN AQUA-AMMONIA ABSORPTION R...
- Auteurs : ATAER O. E.
- Date : 24/09/1990
- Langues : Anglais
- Formats : PDF
Voir la fiche
-
COMPARATIVE STUDY OF IRREVERSIBILITIES IN AN AQ...
- Auteurs : ATAER O. E., GOGUS Y.
- Date : 03/1991
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 14 - n. 2
- Formats : PDF
Voir la fiche