Analyse expérimentale d’une pompe à chaleur à absorption au gaz avec un échangeur de chaleur aux gaz de combustion refroidis par frigorigène.

Experimental analysis of a gas-fired absorption heat pump with a refrigerant cooled flue gas heat exchanger.

Numéro : pap. n. 214

Auteurs : WAGNER P., RIEBERER R.

Résumé

Residential heating has a significant potential in the reduction of energy consumption and CO2 emissions. A relevant contribution can be expected from gas-fired ammonia/water absorption heat pumps (GAHPs). Commonly the return flow of the heat distribution system is used to cool the combustion gas below the dew point to condensate water vapour and to minimize latent heat losses. Especially in retrofit applications the temperature of the heat distribution system is too high to condensate water vapour. To use the latent heat under all operating conditions, a GAHP can be equipped with a refrigerant cooled flue gas heat exchanger between the evaporator and the absorber. Therefore, an increase in efficiency can be achieved. Measurements were carried out to determine the increase in efficiency using a refrigerant cooled flue gas heat exchanger. The GAHP was operated at different operating conditions and different cycle configurations.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental analysis of a gas-fired absorption heat pump with a refrigerant cooled flue gas heat exchanger.
  • Identifiant de la fiche : 30026435
  • Langues : Anglais
  • Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
  • Date d'édition : 24/08/2019
  • DOI : http://dx.doi.org/10.18462/iir.icr.2019.0214

Liens


Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence