Analyse expérimentale et améliorations de la conception d'une turbine à détente Viper à récupération d’énergie et d'un dispositif de séparation de phases d’écoulement appliqués à une pompe à chaleur au R410A.
Experimental analysis and design improvements on combined viper expansion work recovery turbine and flow phase separation device applied in R410A heat pump.
Numéro : pap. 2251
Auteurs : BARTA R. B., SIMON F., GROLL E. A.
Résumé
In light of recent trends towards energy efficiency and environmental consciousness, the heating, ventilation, air conditioning and refrigeration (HVAC&R) industry has been pushing for technological developments to meet both of these needs. As such, several solutions for harnessing the energy released from refrigerants during the free expansion process of a conventional vapor-compression cycle have been developed to increase overall cycle efficiency. The goal of this research is to investigate the potential impact of installing an energy recovery expander, named Viper Expander, into an R410A heat pump cycle and to increase the efficiency of the expander. To improve the expander design, flow visualization of the two-phase refrigerant leaving the nozzle has been performed. Additionally, a housing redesign that would allow the expander to act as both an expansion work recovery device as well as a flash tank economizer has been proposed and tested as a system solution. Implementing phase separation is intended to have the combined effect of reducing turbine performance losses while also serving as an open economizer to increase overall cycle performance. An experimental investigation of these effects is presented herein, with preliminary experimental results of an expander isentropic efficiency of 18%.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental analysis and design improvements on combined viper expansion work recovery turbine and flow phase separation device applied in R410A heat pump.
- Identifiant de la fiche : 30024462
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
HFC;
Systèmes de détente - Mots-clés : R410A; Conception; Réservoir; Pompe à chaleur; Modélisation; Essai; Détente; Frigorigène
-
Thermal performance of ground source heat pumps...
- Auteurs : TAKEDA T., TANAKA D., YOKOYAMA D., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Experimental investigation on the performance o...
- Auteurs : NIU J., WU H., DONG Y.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Transient and steady-state experimental investi...
- Auteurs : XU X., HWANG Y., RADERMACHER R.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche
-
Characteristics of R134a/R410A cascade heat pum...
- Auteurs : KIM D. H., PARK H. S., KIM M. S.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Effects of intermediate pressure on the heating...
- Auteurs : ROH C. W., KIM M. S.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche