Analyse sur site des compresseurs à multiples sections.

Field analysis of multisection compressors.

Auteurs : GRESH K. K.

Type d'article : Article

Résumé

Accurate data and proper analysis are necessary to compare operating data to the manufacturer's guarantee. Proper analysis is required to justify a project whether it involves new equipment, a rerate or an overhaul. Frequent and regular testing is essential to monitor operating expenses and to aid in determining overhaul frequency. Field testing iso-cooled compressors can be straightforward, but a few precautions are advised. In the case of compressors with economizer nozzles, proper side-load compressor analysis requires internal temperature and pressure probes to properly calculate performance of the individual compressor sections.

Détails

  • Titre original : Field analysis of multisection compressors.
  • Identifiant de la fiche : 1999-0119
  • Langues : Anglais
  • Source : Hydrocarbon Processing - vol. 77 - n. 1
  • Date d'édition : 01/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir la source