Analyse théorique et expérimentale du refroidissement au dioxyde de carbone surcritique.

Theoretical and experimental analysis of supercritical carbon dioxide cooling.

Numéro : pap. 2113

Auteurs : ELDIK M. van, HARRIS P. M., KAISER W. H., et al.

Résumé

With on-going developments in the field of trans-critical carbon dioxide (R-744) vapour compression cycles, a need to effectively describe the heat transfer of supercritical carbon dioxide for application in larger diameter tube-in-tube heat exchangers was identified. This study focuses on the in-tube cooling of supercritical carbon dioxide for application in the gas cooler of a trans-critical heat pump. A literature study has revealed there are Nusselt number correlations specifically developed for the cooling of supercritical carbon dioxide. These correlations were proven to be accurate only for certain operating conditions and tube geometries. From the literature review a shortcoming was identified for a generic heat transfer correlation that can be applied over a wide range of fluid conditions for supercritical carbon dioxide cooling. The objective of this study was to compare experimental data obtained from a trans-critical heat pump test bench with different Nusselt number correlations available in literature. The experimental tube diameter used for this study (16mm), which was based on commercially available pipe sizes, was considerably larger than the validated tube diameters used by the researchers who developed Nusselt number correlations specifically for the supercritical cooling of carbon dioxide. The experimental Reynolds number ranges were very high (350,000 < Re < 680,000) compared to those found in literature (Re < 300,000). Experimental results showed that correlations specifically developed for supercritical carbon dioxide cooling generally over-predicts the Nusselt numbers with an average relative error of between 62% and 458% and subsequently also over predicts the convection heat transfer coefficients. Furthermore, generic heat transfer correlations were compared to the experimental results which over-predicted the Nusselt number with an average relative error of between 20% and 45% over the entire Reynolds number range. More specifically, the correlation by Dittus and Boelter (1985) correlated with an average relative error of 9% for 350,000 < Re < 550,000. From the results of this study it was concluded that cooling heat transfer of supercritical carbon dioxide in larger tube diameters and at higher Reynolds numbers is more accurately predicted by the generic Dittus and Boelter (1985) and Gnielinski (1975) correlations mainly due to the absence of thermo-physical property ratios as seen in the CO2-specific correlations.

Documents disponibles

Format PDF

Pages : 10 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Theoretical and experimental analysis of supercritical carbon dioxide cooling.
  • Identifiant de la fiche : 30013199
  • Langues : Anglais
  • Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 14/07/2014

Liens


Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence