Résumé
Nowadays, synthetic refrigerants are being phased out worldwide due to their harmful effects on the ozone layer depletion and global warming. On the other hand, natural substances are being recalled as long-term alternatives for different applications in the refrigeration industry. Moreover, cascade refrigeration systems with CO2 as working fluid in the low temperature stage and NH3 in the high temperature constitute an interesting choice for low temperature (-40/-55°C) cooling applications, such as freezing processes or the storage of frozen products. In the paper, a detailed thermodynamic analysis of a two-stage cascade refrigeration system with CO2 and NH3 as working fluids is reported. The influence of the main design parameters on COP and exergetic efficiency is obtained and discussed. Special attention is paid to the determination of the optimum temperature level to carry out the inter-stage heat transfer process. Moreover, useful maps and correlations are proposed to be used in the design and the optimization of these types of refrigeration systems.
Documents disponibles
Format PDF
Pages : ICR07-B1-1104
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Thermodynamic analysis of a CO2-NH3 cascade refrigeration system.
- Identifiant de la fiche : 2007-2544
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Systèmes à compression;
Ammoniac;
CO2 - Mots-clés : Système frigorifique; Ammoniac; Simulation; Performance; Système en cascade; Modélisation; COP; CO2
-
Carbon dioxide: secondary coolant or refrigeran...
- Auteurs : INFANTE FERREIRA C. A., BOUKENS R. A.
- Date : 03/09/1996
- Langues : Anglais
- Source : Applications for Natural Refrigerants
- Formats : PDF
Voir la fiche
-
Theoretical analysis of a CO2-NH3 cascade refri...
- Auteurs : DOPAZO J. A., FERNÁNDEZ-SEARA J., SIERES J., et al.
- Date : 06/2009
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 29 - n. 8-9
Voir la fiche
-
Thermodynamic analysis of optimal condensing te...
- Auteurs : LEE T. S., LIU C. H., CHEN T. W.
- Date : 11/2006
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 29 - n. 7
- Formats : PDF
Voir la fiche
-
Simulation model of a CO2/NH3 cascade refrigera...
- Auteurs : FERNÁNDEZ-SEARA J., ARIAS A., DOPAZO A., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Natural gas mixtures as working fluids for casc...
- Auteurs : DI NICOLA G., GIULIANI G., POLONARA F., et al.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche