Analyse thermodynamique et environnementale d’un cycle frigorifique au CO2 transcritique modifié avec un éjecteur et un sous-refroidisseur.
Thermodynamic and environment analysis of a modified transcritical CO2 refrigeration cycle integrated with ejector and subcooler.
Résumé
The traditional transcritical CO2 two-stage compression refrigeration cycle (TTRC) has a great advantage in supermarket refrigeration applications. Currently, however, the performance of the TTRC still has the potential to be improved. In this paper, an ejector-enhanced transcritical two-stage compression CO2 cycle is presented for supermarket refrigeration application. Based on the basic TTRC with a subcooler, a flash tank, an ejector and are introduced. On the one hand, part of the expansion work can be recovered by the ejector. Moreover, the subcooler is employed to increase the subcooling degree of refrigerant entering the expansion valve, which could increase the evaporator's cooling capacity. The cycle performances of the cycles are theoretically studied by energy, exergy and carbon footprint evaluation. Meanwhile, the intermediate pressures of the two cycles are also optimized. Under optimum intermediate pressure, the energy analyses show that the coefficient of performance is improved by 9.6–11.0% and the volume cooling capacity is enhanced by 14.5%-18.4% with the modified cycle. Moreover, the exergy analysis indicates that the expansion valves account for 27.1% of the exergy destruction of the basic cycle, while it is just 7.51% for the modified cycle. The carbon footprint analysis shows that the modified system with CO2 refrigerant could reduce carbon emissions by 17.95% compared to the conventional refrigerant R404A. It shows the feasibility of using CO2 to replace R404A refrigerant in commercial supermarket refrigeration, and has significant eco-friendly benefits.
Documents disponibles
Format PDF
Pages : 123-138
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Thermodynamic and environment analysis of a modified transcritical CO2 refrigeration cycle integrated with ejector and subcooler.
- Identifiant de la fiche : 30033827
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 173
- Date d'édition : 05/2025
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2025.02.012
Liens
Voir d'autres articles du même numéro (17)
Voir la source
Indexation
-
Simulation and optimization of a R744 two- temp...
- Auteurs : HUANG Z., ZHAO H., YU Z., et al.
- Date : 06/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 90
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis of a modified two-stage ...
- Auteurs : LI H., HUANG Q., YU J.
- Date : 12/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 168
- Formats : PDF
Voir la fiche
-
Comparative thermodynamic study of CO2
- Auteurs : JIANG J., YANG Q., YIN T., ZHENG Z., ZHAO Y., LIU G., LI L.
- Date : 02/2025
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 170
- Formats : PDF
Voir la fiche
-
Thermodynamic study of carbon dioxide transcrit...
- Auteurs : HUANG C., LI Z., YE Z., WANG R.
- Date : 05/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 137
- Formats : PDF
Voir la fiche
-
Performance analysis of a modified dual-ejector...
- Auteurs : LIU J., YU J.
- Date : 11/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Formats : PDF
Voir la fiche