Document IIF
Analyses de l’énergie, de l’exergie et de l’entransie d’un régénérateur de déshydratant liquide.
Energy, entransy and exergy analyses of a liquid desiccant regenerator.
Auteurs : NAIK K., MUTHUKUMAR P.
Type d'article : Article, Article de la RIF
Résumé
In the present study, the energy exchange between the liquid desiccant and the ambient air, entransy dissipation during coupled heat and mass transfer processes and exergy destruction with respect to the reference state for the liquid desiccant regenerator are analyzed. Expressions for energy, exergy and entransy (EEE) of the regenerator are derived and also quantified along the height of the liquid desiccant regenerator. By varying the operating parameters such as desiccant temperature and concentration, air temperature and humidity ratio and air and desiccant flow rates, the performance of the regenerator is investigated in terms of entransy, exergy and desorption efficiencies. From the EEE analyses, it is observed that by increasing the desiccant temperature from 60.3 °C to 65.2 °C and decreasing the air humidity ra- tio from 18.7 g wv /kg da to 14.3 g wv /kg da simultaneously, the overall energy exchange, exergy destruction and entransy dissipation are increased by 26%, 37% and 39%, respectively. Further, the entropy generation along the tower height is also investigated and observed that for a given set of operating conditions, with increase in distance along the tower height, the entropy generation increases by 96% and decreases by 35% for the air side and the solution side, respectively.
Documents disponibles
Format PDF
Pages : 80-91
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy, entransy and exergy analyses of a liquid desiccant regenerator.
- Identifiant de la fiche : 30026907
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 105
- Date d'édition : 09/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.08.016
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Energy, entransy and exergy analyses of a liqui...
- Auteurs : BUCKE K. N., PALANISAMY M.
- Date : 07/08/2017
- Langues : Anglais
- Source : International sorption heat pump conference, ISHPC 2017, Tokyo august 7-10.
Voir la fiche
-
Numerical study on internally cooled-heated deh...
- Auteurs : YIN Y., ZHANG X. S.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Exergy analysis of a liquid desiccant based, hy...
- Auteurs : AHMED C. S. K., GANDHIDASAN P., et al.
- Date : 01/1998
- Langues : Anglais
- Source : Energy, Int. J. - vol. 23 - n. 1
Voir la fiche
-
Liquid desiccant-based deep dehumidifier workin...
- Auteurs : CAO B., YIN Y., ZHANG F., JI Q., CHEN W.
- Date : 02/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 146
- Formats : PDF
Voir la fiche
-
Performance characteristics for a desiccant sys...
- Auteurs : VINEYARD E. A., SAND J. R., DURFEE D. J.
- Date : 2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
Voir la fiche