Résumé
At present, there are two main circulation modes for the expansion cycle of the ejector, one is standard ejector-expansion cycle (SEC), and the other is ejector-expansion recirculation cycle (ERC). In this study, the zeotropic mixture R744/R1234yf are used as the working fluid. And the performance of the ERC in heat pump application is evaluated by utilizing energetic and exergetic analysis methods. The effects of evaporator outlet temperature (Te), condenser outlet temperature (Tc) and CO2 mass fraction (ZCO2) on the cycle performance are investigated, and the results demonstrate that ERC exhibits better cycle performance than SEC. The maximum COP and volumetric heating capacity ( qcv ) of ERC improve by 24.6% and 37.7% at most compared to those of SEC, respectively. Compared to SEC, the exergy destruction of ERC is reduced by 29.8% on average. Furthermore, under given mass fraction range, the volumetric heating capacity increase with increasing of R1234yf fraction. The simulation results show that the ejector-expansion recirculation cycle has more obvious advantages when using mixed refrigerant.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy and exergy analyses of an ejector-expansion recirculation cycle with zeotropic mixture R744/R1234yf for application in heat pumps.
- Identifiant de la fiche : 30031024
- Langues : Anglais
- Sujet : Technologie
- Source : 3rd IIR conference on HFO Refrigerants and low GWP Blends. Shanghai, China.
- Date d'édition : 05/04/2023
- DOI : http://dx.doi.org/10.18462/iir.HFO2023.0014
Liens
Voir d'autres communications du même compte rendu (28)
Voir le compte rendu de la conférence
-
The effect of fractionation inside the storage ...
- Auteurs : HAIDER M.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Investigation on ejector design for CO2
- Auteurs : METSUE A., BARTOSIEWICZ Y., PONCET S.
- Date : 16/09/2021
- Langues : Anglais
- Source : 9th IIR Conference on Ammonia and CO2 Refrigeration Technologies. Proceedings: Ohrid, North Macedonia, 16-17 September, 2021
- Formats : PDF
Voir la fiche
-
Effect of fractionation on ejector and system p...
- Auteurs : HAIDER M., ELBEL S.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis of a modified vapor-inje...
- Auteurs : ZHAO Y., YU J.
- Date : 01/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Formats : PDF
Voir la fiche
-
Dynamic simulation study on regulation characte...
- Auteurs : XIONG Z., HE Y., ZHAO H., DENG J.
- Date : 06/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 150
- Formats : PDF
Voir la fiche