Application d'un système de régulation hybride des détendeurs à une pompe à chaleur domestique et à un système frigorifique pour chambre froide.
Application of a hybrid control of expansion valves to a domestic heat pump and a walk-in cooler refrigeration system.
Auteurs : BACH C. K., GROLL E. A., BRAUN J. E., et al.
Type d'article : Article
Résumé
Hybrid refrigerant flow control, as proposed by Kim et al. (2008), employs a primary expansion valve that provides most of the pressure drop between the condensing and evaporation pressures, while small secondary balancing valves in the distributor lines to the circuits of the evaporator adjust the refrigerant flow to provide equal circuit exit superheats. In this article, experimental results for the application of the hybrid control of expansion valves to a 3-ton (10.6-kW) R404A walk-in cooler refrigeration system and a 5-ton (17.6-kW) domestic heat pump are presented. For the walk-in cooler refrigeration, initial data was taken using the inbuilt thermostatic expansion valve. Baseline data with an electronic expansion valve was taken for both systems to determine the best possible performance without using individual circuit flow control. After that, secondary balancing valves were inserted into the distributor lines to complete the hybrid control scheme. The tests were repeated to determine the achievable performance improvement. Frost build up tests at high indoor room humidity were conducted with all control schemes to determine the influence of the control scheme on frost distribution and system performance. To determine the influence of a fixed and repeatable airside maldistribution, additional tests with partially blocked evaporator coils were conducted for both units with the electronic expansion valve and hybrid control scheme.
Détails
- Titre original : Application of a hybrid control of expansion valves to a domestic heat pump and a walk-in cooler refrigeration system.
- Identifiant de la fiche : 30010561
- Langues : Anglais
- Source : HVAC&R Research - vol. 19 - n. 7
- Date d'édition : 10/2013
- DOI : http://dx.doi.org/10.1080/10789669.2013.822251
Liens
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
-
Application of a hybrid control of expansion va...
- Auteurs : BACH C. K., GROLL E. A., BRAUN J. E.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental investigation on single fault impa...
- Auteurs : KIM S., KU D., CHUNG J. D., KIM M.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Performance characteristics of a simultaneous c...
- Auteurs : JOO Y., KANG H., AHN J. H., et al.
- Date : 06/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 4
- Formats : PDF
Voir la fiche
-
Mass flow characteristics and correlations of R...
- Auteurs : HOU W., LIU H., BRAUN J. E., GROLL E. A., ZIVIANI D.
- Date : 11/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 155
- Formats : PDF
Voir la fiche
-
Experimental quantification of liquid line temp...
- Auteurs : HU Y., YUILL D. P., CHEN Y.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche