Résumé
This work advances a technique for fault detection and diagnosis (FDD) in single-door refrigerating appliances based on a heuristic decision tree developed on thermodynamic grounds. Four faults were considered, namely condenser fouling, evaporator frosting, refrigerant leakage, and non-condensable gas contamination. The experiments were carried out using an ice cream display cabinet fully instrumented with pressure transducers, temperature sensors, and power meters. To ensure practical applicability in real appliances, the FDD algorithm was devised to rely on minimal instrumentation and data, therefore requiring only three additional temperature sensors in addition to the electric variables available from the compressor motor driver. Moreover, only two setup tests conducted at the minimum and maximum surrounding air temperatures with the system operating under no-fault condition were required. The approach was devised based on real time estimation of a normalized COP and validated using experimental data obtained for three different surrounding air temperatures (20°C, 25°C and 32°C) with single faults imposed. As the result, an average accuracy higher than 90% was achieved while rejecting false positives such as door openings and defrosting operations.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Gratuit
Détails
- Titre original : COP-based decision tree for fault detection and diagnosis in single-door refrigerating appliances.
- Identifiant de la fiche : 30032975
- Langues : Anglais
- Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 17/07/2024
Liens
Voir d'autres communications du même compte rendu (187)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Panne; Détection; Meuble de vente; COP; Experimentation
-
Performance variation of vertical open refriger...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D., et al.
- Date : 23/06/2014
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Formats : PDF
Voir la fiche
-
Research on temperature distribution in vertica...
- Auteurs : LU Y. L., XUE M. D., YUAN P., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Improvement of temperature uniformity in open r...
- Auteurs : LIN H. W., CHEN Y. F., HSIEH W. D., et al.
- Date : 20/05/2009
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
Voir la fiche
-
The realization and evaluation of utilizing nat...
- Auteurs : CHEN T., LIN W., YU K., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Investigation of energy-efficient supermarket d...
- Auteurs : WALKER D. H., FARAMARZI R. T., BAXTER V. D.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche