Document IIF

Calcul et vérification expérimentale du coefficient de transfert de chaleur d'un évaporateur au méthanol à faible pression.

Calculation and experimental verification of heat transfer coefficient for low pressure methanol evaporator.

Numéro : pap. n. 296

Auteurs : HALON T., ZAJACZKOWSKI B., KRÓLICKI Z., et al.

Résumé

Natural refrigerants are attracting attention due to their environmental neutrality. They have good thermal properties, but their evaporation pressures at near room temperatures are just a few kPa. There is limited information regarding evaporation of methanol at low-pressures. Empirical correlations for boiling heat transfer coefficient that were developed at atmospheric pressure levels tend to give high errors. In this paper we show an experimental data for pool boiling of methanol in pressure region 0.3–18 kPa and heat fluxes 10–45 kW/m2. The results are compared to calculations based on eight empirical heat transfer coefficient correlations. Since all of them yielded noticable errors, we suggested new constants for the power law equation that allow more accurate prediction of heat transfer coefficient.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Calculation and experimental verification of heat transfer coefficient for low pressure methanol evaporator.
  • Identifiant de la fiche : 30016135
  • Langues : Anglais
  • Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
  • Date d'édition : 16/08/2015
  • DOI : http://dx.doi.org/10.18462/iir.icr.2015.0296

Liens


Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence