Document IIF
Caractérisation de la mauvaise distribution hydraulique dans un échangeur de chaleur par mesure locale des coefficients de transfert de chaleur utilisant la thermographie infrarouge.
Characterisation of the hydraulic maldistribution in a heat exchanger by local measurement of convective heat transfer coefficients using infrared thermography.
Auteurs : LEBLAY P., HENRY J. F., CARON D., et al.
Type d'article : Article, Article de la RIF
Résumé
A methodology was developed to characterise the heat exchangers' performance decrease due to two-phase flow maldistribution. It consists in measuring the spatial distribution of the local heat transfer coefficients with a rapid, non-invasive and fluid independent method. The method is based on the infrared (IR) thermography measurement of the temperature response to an oscillating heat flux. The amplitude of the measured temperatures is compared to the solution of an analytical model. The problem is solved iteratively to obtain the heat transfer coefficients. This method has been applied to evaluate the uneven phase distribution of an air–water mixture in a compact heat exchanger. The exchanger is composed of seven multiport flat tubes, a vertical downward header and horizontal channels. Experiments were performed for mass flux from 29 kg m-2 s-1 to 116 kg m-2 s-1 and for quality from 0.10 to 0.70.
Documents disponibles
Format PDF
Pages : 73-82
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Characterisation of the hydraulic maldistribution in a heat exchanger by local measurement of convective heat transfer coefficients using infrared thermography.
- Identifiant de la fiche : 30011949
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 45
- Date d'édition : 09/2014
Liens
Voir d'autres articles du même numéro (23)
Voir la source
-
Infrared thermography measurement of two-phase ...
- Auteurs : LIU T. L., PAN C.
- Date : 05/02/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 94
Voir la fiche
-
Quantification of liquid refrigerant distributi...
- Auteurs : LI H., HRNJAK P.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Quantification of two-phase refrigerant distrib...
- Auteurs : LI W., HRNJAK P.
- Date : 11/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Formats : PDF
Voir la fiche
-
An experimentally validated model for microchan...
- Auteurs : LI H., HRNJAK P.
- Date : 11/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 59
- Formats : PDF
Voir la fiche
-
IR thermography measurement of convective heat ...
- Auteurs : LEBLAY P., HENRY J. F., CARON D., et al.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.