Caractéristiques d'écoulement et de transfert de chaleur d'un système de refroidissement indirect sec avec cadres d'échangeur de chaleur horizontaux en forme de A sous conditions de vents ambiants.
Flow and heat transfer characteristics of indirect dry cooling system with horizontal heat exchanger A-frames at ambient winds.
Auteurs : WU X. P., YANG L. J., DU X. Z., et al.
Type d'article : Article
Résumé
Ambient winds are key issues in the operation of indirect dry cooling system in power plants, so it is of use to make clear the thermo-hydraulic performances of indirect dry cooling system at ambient winds. On the basis of two indirect dry cooling systems with horizontally arranged heat exchanger bundles in the patterns of radial and rectangular A-frames, the computational models of air-side flow and heat transfer coupled with the performances of the circulating water and exhaust steam are developed. The velocity, pressure and temperature fields of cooling air in the absence and presence of winds are presented and the average mass flow rate of cooling air, inlet air temperature as well as the heat rejection for the A-frames of each cooling sector of the air-cooled heat exchanger are calculated, by which the outlet water temperature of heat exchanger and the back pressure of turbine are obtained. The results show that the wind effects on the thermo-hydraulic performances of indirect dry cooling system differ completely from those with vertically arranged air-cooled heat exchanger outside. The velocity and temperature fields present central symmetric characteristics for the heat exchanger in the radial pattern, however, the differences are observed for the heat exchanger A-frames in the rectangular pattern. The thermo-hydraulic performances of the upwind A-frames are most deteriorated by the adverse impacts of ambient winds, but they are improved for the downwind ones, just similar to those of direct dry cooling system. As the wind speed increases, the mass flow rate and heat rejection of the downwind A-frames increase, but they are reduced for the upwind ones. The outlet water temperature of the heat exchanger and back pressure of turbine increase with increasing wind speed. The investigation of wind effects on the flow and heat transfer characteristics of indirect dry cooling system with horizontal heat exchanger A-frames is of benefit to the design and operation of air-cooled heat exchangers and cooling towers.
Détails
- Titre original : Flow and heat transfer characteristics of indirect dry cooling system with horizontal heat exchanger A-frames at ambient winds.
- Identifiant de la fiche : 30010686
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 79
- Date d'édition : 05/2014
- DOI : http://dx.doi.org/10.1016/j.ijthermalsci.2014.01.007
Liens
Voir d'autres articles du même numéro (2)
Voir la source
-
Cross scale simulation on transport phenomena o...
- Auteurs : HU H., DU X., YANG L., et al.
- Date : 08/2014
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 75
Voir la fiche
-
POD-based modeling on thermal-flow characterist...
- Auteurs : HU H., DU X., YANG L., et al.
- Date : 02/2014
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 76
Voir la fiche
-
Experimental investigation on the performance o...
- Auteurs : NING T., CHONG D., JIA M., et al.
- Date : 03/2015
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 78
Voir la fiche
-
A novel natural draft dry cooling system with b...
- Auteurs : KONG Y., WANG W., YANG L., et al.
- Date : 02/2017
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 112
Voir la fiche
-
Monitoring and assessment of an industrial anti...
- Auteurs : RUBIO D., LÓPEZ-GALINDO C., CASANUEVA J. F., et al.
- Date : 06/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 67 - n. 1-2
Voir la fiche