Résumé
This article is the Spanish translation of an article presented at the IIR conference in Melbourne, Australia (see the Bulletin of the IIR, reference 2009-1769). Supermarkets use 4% of the USA power grid and 2.2% of the Australian national grid. The typical supermarket uses five times more energy than a typical office building. The refrigerated cases account for about 50% of a typical supermarket energy consumption. Since up to 80% of the refrigerated case is load is from the store, energy savings opportunities in HVAC and refrigeration can result from effective humidity control. This paper focuses on the treatment of outside ventilation air with which accounts for 80-90% of the latent load in a supermarket. Energy modelling of various HVAC systems for RH control is needed for the comparison with refrigeration costs. The paper also analyzes the reduction in refrigerated case operating costs at lower humidity levels. Technical developments in desiccants used as dedicated outdoor air systems can be applied to optimize these energy savings.
Documents disponibles
Format PDF
Pages : pp. 22-30 (8 p.)
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : HVAC en supermercado y evaluación de la energía para refrigeración.
- Identifiant de la fiche : 2010-1630
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 38 - n. 425
- Date d'édition : 05/2010
Liens
- Voir les traductions : Supermarket HVAC and refrigeration energy evaluation.
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
-
Diseño integral de AC y refrigeración en superm...
- Auteurs : GUTIÉRREZ J. C.
- Date : 09/2003
- Langues : Espagnol
- Source : ACR-Latinoam. - vol. 6 - n. 5
Voir la fiche
-
Desiccant assisted cooling: Coles supermarket.
- Auteurs : CHEONG J., BEVERN J.
- Date : 12/1996
- Langues : Anglais
- Source : AIRAH J. - vol. 50 - n. 12
Voir la fiche
-
Gas-fired rooftop desiccant unit brings multipl...
- Auteurs : NORLAND J.
- Date : 14/11/1994
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News - vol. 193 - n. 11
Voir la fiche
-
Evaluación de los ahorros energéticos recuperan...
- Auteurs : CORTELLA G., SARO O.
- Date : 09/2011
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 39 - n. 439
- Formats : PDF
Voir la fiche
-
INTEREFFECTS IN SUPERMARKETS.
- Auteurs : ADAMS P. Jr
- Date : 10/1985
- Langues : Anglais
- Source : ASHRAE Journal - vol. 27 - n. 10
Voir la fiche