Comparaison des performances des générateurs thermoacoustiques muni d'un tube résonant de diamètre constant et d'un tube résonant de section triangulaire.
Performance comparison of thermoacoustic engines with constant-diameter resonant tube and tapered resonant tube.
Auteurs : TANG K., CHEN G. B., JIN T., et al.
Type d'article : Article
Résumé
Two standing-wave thermoacoustic engines with a constant-diameter resonant tube and a tapered one, respectively, are simulatedwith linear thermoacoustics to explore the reasons for performance improvement of the thermoacoustic engine with the tapered resonanttube substituting for the constant-diameter one. Computed results indicate that the viscous loss in the tapered resonant tube is muchlower than that in the constant-diameter one, and the smooth joint between the tapered resonant tube and its resonant cavity may avoidthe acoustic power loss derived from sharp variation of flow area. The comparison between the computed results and the experimentaldata indicates that the simulation can roughly predict the performance of thermoacoustic engines with these two types of resonant tubes. [Reprinted with permission from Elsevier. Copyright, 2006].
Détails
- Titre original : Performance comparison of thermoacoustic engines with constant-diameter resonant tube and tapered resonant tube.
- Identifiant de la fiche : 2007-0928
- Langues : Anglais
- Source : Cryogenics - vol. 46 - n. 10
- Date d'édition : 10/2006
Liens
Voir d'autres articles du même numéro (2)
Voir la source
Indexation
-
Measurements of the flow resistance and inducta...
- Auteurs : JU Y. L., YUAN K., HE G. Q., et al.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche
-
Frequency characteristics of a thermoacoustic p...
- Auteurs : TANG K., CHEN G. B., HUANG Y. H.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche
-
Design and performance analysis of small cryoge...
- Auteurs : ZHANG L. H., JU Y. L., LIANG J. T.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche
-
Thermodynamic comparison of two types of Stirli...
- Auteurs : WU Z. H., LUO E. C., DAI W., et al.
- Date : 14/06/2006
- Langues : Anglais
Voir la fiche
-
Experimental investigation on DC flow control i...
- Auteurs : JIANG Y. L., CHEN G. B., THUMMES G.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche