Document IIF
Comparaison des performances des systèmes alternatifs au R404A à très faible GWP pour un congélateur commercial.
Performance comparison of very low GWP R404A alternatives in a commercial freezer application
Numéro : pap. n. 0236
Auteurs : SPLETZER S., MEDINA J., ROBERTS N.
Résumé
International efforts to reduce the global warming impact of refrigerants are advancing, as evidenced by the Kigali Agreement and European F-Gas regulations. R-404A is widely used for medium and low temperature refrigeration applications. Given the GWP of this HFC blend (GWP100 Year = 3,922 per AR4), lower GWP alternatives are required. For smaller self-contained equipment, several new very low GWP HFC-HFO blends are now under consideration, such as XL40 (R-454A), XL20 (R-454C), and R-455A. While mildy flammable, these products allow for significantly larger charge sizes than the highly flammable hydrocarbons.
Soft-optimized system testing was conducted to quantify the relative performance, to R-404A, of these alternatives using a commercially available two-door reach-in freezer. Energy consumption and other operating characteristics were monitored, as well as potential impacts on compressor functionality (e.g. lubrication).
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance comparison of very low GWP R404A alternatives in a commercial freezer application
- Identifiant de la fiche : 30022414
- Langues : Anglais
- Sujet : Réglementation
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Date d'édition : 06/09/2017
- DOI : http://dx.doi.org/10.18462/iir.compr.2017.0236
Liens
Voir d'autres communications du même compte rendu (35)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Frigorigènes, frigoporteurs : réglementation et normes - Mots-clés : Consommation d'énergie; Faible GWP; R404A; Inflammabilité; HFO; Essai; COP; Conversion; Congélateur; Compresseur
-
Safety research of mildly flammable refrigerant...
- Auteurs : HIHARA E.
- Date : 23/04/2017
- Langues : Anglais
- Source : 5th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants.
- Formats : PDF
Voir la fiche
-
Low GWP refrigerants era has started – Compress...
- Auteurs : ZGLICZYNSKI M.
- Date : 06/09/2017
- Langues : Anglais
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche
-
A primer on refrigerants. 3.
- Auteurs : RAVINDRA D.
- Date : 03/2014
- Langues : Anglais
- Source : Air Conditioning and Refrigeration Journal - vol. 17 - n. 2
- Formats : PDF
Voir la fiche
-
Guidance on the future use of R404A and the new...
- Auteurs : ACRIB
- Date : 11/2014
- Langues : Anglais
- Source : http://www.acrib.org.uk
Voir la fiche
-
An overview of how flammable refrigerants are c...
- Auteurs : SPLETZER S., COUGHLAN P., GERSTEL J.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche