Résumé

International efforts to reduce the global warming impact of refrigerants are advancing, as evidenced by the Kigali Agreement and European F-Gas regulations. R-404A is widely used for medium and low temperature refrigeration applications. Given the GWP of this HFC blend (GWP100 Year = 3,922 per AR4), lower GWP alternatives are required. For smaller self-contained equipment, several new very low GWP HFC-HFO blends are now under consideration, such as XL40 (R-454A), XL20 (R-454C), and R-455A. While mildy flammable, these products allow for significantly larger charge sizes than the highly flammable hydrocarbons.
Soft-optimized system testing was conducted to quantify the relative performance, to R-404A, of these alternatives using a commercially available two-door reach-in freezer. Energy consumption and other operating characteristics were monitored, as well as potential impacts on compressor functionality (e.g. lubrication).

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Performance comparison of very low GWP R404A alternatives in a commercial freezer application
  • Identifiant de la fiche : 30022414
  • Langues : Anglais
  • Sujet : Réglementation
  • Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
  • Date d'édition : 06/09/2017
  • DOI : http://dx.doi.org/10.18462/iir.compr.2017.0236

Liens


Voir d'autres communications du même compte rendu (35)
Voir le compte rendu de la conférence