Comportement des systèmes de chauffage dans les conditions non prévues par la conception et influence sur la performance prévue des pompes à chaleur.
El comportamiento de sistemas de calefacción bajo condiciones fuera de diseño e influencia sobre el rendimiento de deseño de la bomba de calor.
Auteurs : NIELSEN G.
Type d'article : Article de périodique
Résumé
This article is the Spanish translation of an article presented at the IIR conference in Ohrid, Macedonia (see the Bulletin of the IIR, reference 2007-2313). The behaviour of heating systems, working at off-design conditions, has as a whole been neglected by practitioners and researchers alike. With increasing the use of heat pumps in heating systems, this lack of knowledge leads to systems that in their overall design has serious flaws, i.e. systems that are run poorly, systems where the heat pump capacity is too high, systems with unnecessary big radiators and systems where the heat pumps are designed for unnecessary high pressure levels. In this paper, the author shows that for a typical office building the use either of low temperature heating systems or high pressure class NH3 heat pumps, will only give an extra heat delivery of approximately 3%. The point is then, is the 3% worth the extra investment? The author shows that usually, from an economic point of view, it's not.
Documents disponibles
Format PDF
Pages : 32-44 (10 p.)
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : El comportamiento de sistemas de calefacción bajo condiciones fuera de diseño e influencia sobre el rendimiento de deseño de la bomba de calor.
- Identifiant de la fiche : 2009-0388
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 36 - n. 408
- Date d'édition : 11/2008
Liens
- Voir les traductions : The behaviour of heating systems at off-design conditions and the influence on heat pump design performance.
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
-
Thèmes :
Ammoniac;
Autres applications des pompes à chaleur - Mots-clés : Bureau; Calcul; Immeuble; Amortissement économique; Ammoniac; Simulation; Pompe à chaleur; Chauffage; Eau-eau
-
The behaviour of heating systems at off-design ...
- Auteurs : NIELSEN G.
- Date : 19/04/2007
- Langues : Anglais
- Source : Ammonia Refrigeration Technology for Today and Tomorrow.
- Formats : PDF
Voir la fiche
-
LES POMPES A CHALEUR DANS LA CONSTRUCTION NEUVE...
- Date : 1982
- Langues : Français
Voir la fiche
-
Software tools for heat pump design: improving ...
- Auteurs : AFJEI T., BAUMGARTNER T., EICHER H., STALDER M., WITTWER D.
- Date : 06/1995
- Langues : Anglais
- Source : IEA HPC Newsl. - vol. 13 - n. 2
Voir la fiche
-
RENTABILITE DES POMPES A CHALEUR BIVALENTES AIR...
- Auteurs : MICHEL A.
- Date : 02/1983
- Langues : Allemand
- Source : Heiz. Lüft.-Klima Haustech. - vol. 34 - n. 2
Voir la fiche
-
Gasmotor aangedreven warmte pomp installatie vo...
- Auteurs : STOUTHART F. J.
- Date : 03/2004
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 97 - n. 3
Voir la fiche