Document IIF

Concentration d'huile dans les frigorigènes liquides : mesures sur le terrain.

Oil concentration in liquid refrigerants: in situ measurement.

Auteurs : ANDRADE E. Navarro de, SKOWRON E., GOLDSCHMIDT V. W., GROLL E. A.

Type d'article : Article, Article de la RIF

Résumé

The concentration of oil in refrigerants (while in liquid state) can be measured with an acoustic velocity sensor. The transit time for an acoustic signal can be related to the oil concentration and temperature of the liquid mixture. The performance of the sensor is dependent on the properties of the oil and refrigerant, and their miscibility. In general, a thorough calibration becomes necessary. It is shown in this paper that the concentrations less than 10%, an approximation can be made for the estimate of concentration hence eliminating the need for an elaborate calibration procedure.

Documents disponibles

Format PDF

Pages : 499-508

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Oil concentration in liquid refrigerants: in situ measurement.
  • Identifiant de la fiche : 2000-0048
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 22 - n. 6
  • Date d'édition : 09/1999

Liens


Voir d'autres articles du même numéro (5)
Voir la source

Indexation