Conception d'échangeurs de chaleur à tubes en cuivre de 5 mm pour les meubles de vente au R404A.
Design of 5 mm copper tube heat exchangers for display cabinets with R404A.
Numéro : 2331
Auteurs : SONG K., GAO F., SHABTAY Y.
Résumé
Charge reduction is a subject of ongoing research on refrigerated display cabinets. The present paper describes design principles for display cabinets that use copper tubes. In one case study of display cabinets using R404A as a refrigerant, the heat exchanger of the original refrigeration system made from 9.52 mm diameter copper tubes is replaced with an equivalent capacity heat exchanger made from 5 mm diameter copper tubes with enhanced internal surfaces. Performance was optimized using HXSim software, an easy-to-learn simulation tool available from the International Copper Association. The case study demonstrates design principles and presents various results for a typical 2.2 kW display cabinet refrigeration system that uses R404A as a refrigerant. Reduced-charge systems use tube-fin heat exchangers with distributed flow paths and 5 mm copper tubes. The optimized system uses 14.3 percent less charge than the original system. As hydrofluorocarbon (HFC or F-Gas) refrigerants are phased out or tightly regulated globally, manufacturers are seeking to reduce refrigerant charge, eliminate leaks and facilitate recycling. The present case study quantifies how much charge reduction can be realized using smaller-diameter copper tubes in refrigeration equipment with a conventional refrigerant. Similar design principles and heat exchanger simulations could also be used in the design of refrigeration equipment that uses low-GWP refrigerants, including natural refrigerants and HFO-HFC blends.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Gratuit
Détails
- Titre original : Design of 5 mm copper tube heat exchangers for display cabinets with R404A.
- Identifiant de la fiche : 30030661
- Langues : Anglais
- Sujet : Technologie
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 2022
Liens
Voir d'autres communications du même compte rendu (224)
Voir le compte rendu de la conférence
-
Simulation of the effects of copper tube diamet...
- Auteurs : SHABTAY Y., GAO F., SONG K.
- Date : 01/09/2021
- Langues : Anglais
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Optimization of copper-tube coils for energy-ef...
- Auteurs : COTTON N., STILLMAN H., NASUTA D., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Tree-shaped two-phase fluid distributor for mic...
- Auteurs : BRAUNGARDT S., SCHULTZ N., LANGNER R., et al.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
Low charge ammonia shell and tube evaporators: ...
- Auteurs : AYUB Z.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
Design optimization of high performance, reduce...
- Auteurs : TANCABEL J., AUTE V., LING J., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche