Conception d’un système de conditionnement d’air au CO2 transcritique utilisant les nouvelles cartographies de performance de l’éjecteur.

System designing of transcritical CO2 air conditioning system using the novel ejector performance maps.

Numéro : 2528

Auteurs : HAIDER M., ELBEL S.

Résumé

Awareness about the climate impact of air conditioning systems has given impetus in developing environment-friendly solutions. The transcritical CO2 cycle with an ejector as a work recovery device has been reported as one of the green solutions in the literature. However, commercial applicability of these systems is limited so far despite their offered potential. One of the major impediments for limited commercial usage is unavailability of a systematic approach for system design that can help system designers in finding the optimum component combination for their application. For materializing system design approach, it is imperative to develop a system model that can accurately predict performance for wide range of operating conditions while considering different possible component combinations. In this paper, an ejector system model is developed using individual component models of ejector, evaporator, and compressor. The ejector is being modeled using the ejector performance maps, a recently developed methodology for representing ejector performance of a fixed-geometry ejector. The ejector performance maps are accurate, yet they can predict ejector performance for wide range of operation. The evaporator is modeled using geometric parameters, and the refrigerant and the air-side operating conditions, whereas other heat exchangers are modeled using thermodynamic state analysis. The compressor is modeled using semi-empirical correlations by curve-fitting ten-coefficient polynomial using compressor speed and pressure ratio as characterizing variables. The system analysis considers a total of eight component combinations for transcritical CO2 ejector cycle and helps in finding the combination that gives the optimum performance. The results are encouraging as the system analysis using ejector performance maps can help in designing new improved systems. The methodology can also be tested for designing ejector air conditioning systems using other refrigerants.

Documents disponibles

Format PDF

Pages : 10

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : System designing of transcritical CO2 air conditioning system using the novel ejector performance maps.
  • Identifiant de la fiche : 30028541
  • Langues : Anglais
  • Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 05/2021
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (184)
Voir le compte rendu de la conférence