Résumé
A split evaporative air conditioner of evaporative cooling and semiconductor refrigeration was designed. Principle and three modes of operation were discussed, and the design step of split air conditioner was summarized. The water and air temperature of split air conditioner were tested with the experimental prototype. The results show that the air temperature of outdoor unit is about 3-4 °C higher than outdoor wet bulb temperature. The water temperature of outdoor unit is about 1-2 °C lower than outdoor wet bulb temperature. After decreasing by semiconductor refrigeration again, it can be about 4-5 °C lower than the outdoor wet bulb temperature. According to the test results, combined with meteorological data, the air and water temperature in 228 cities in China was calculated. The calculated results show that the split evaporative air conditioner is widely adopted in Northwest China and other dry areas. The applicable rate is over 90%.
Documents disponibles
Format PDF
Pages : 38-43
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 30019768
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 35 - n. 159
- Date d'édition : 10/2014
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2014.05.038
Liens
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
- Thèmes : Equipements d'humidification/déshumidification
- Mots-clés : Système split; Conditionneur d'air; Conception; Système évaporatif; Essai; Charge partielle
-
Evaporative cooling pads: test procedure and ev...
- Auteurs : KOCA R. W., HUGHES W. C., CHRISTIANSON L. L.
- Date : 1991
- Langues : Anglais
- Source : Appl. Eng. Agric. - vol. 7 - n. 4
Voir la fiche
-
The seasonal performance of a liquid-desiccant ...
- Auteurs : LOWENSTEIN A., NOVOSEL D.
- Date : 01/1995
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
Analyse et vérification de l'efficacité de refr...
- Auteurs : WANG W., HUANG X., SUN T., et al.
- Date : 01/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 273
- Formats : PDF
Voir la fiche
-
Conditionnement d'air par deshumidification par...
- Auteurs : BISCHOFF M., DOERK H., KIPPING D. E., NEY A.
- Date : 02/1994
- Langues : Allemand
- Source : KI Luft Kältetech. - vol. 30 - n. 2
Voir la fiche
-
Déshumidification de l'air par sorption et refr...
- Auteurs : FRANZKE U.
- Date : 02/1994
- Langues : Allemand
- Source : KI Luft Kältetech. - vol. 30 - n. 2
Voir la fiche