Summary
A split evaporative air conditioner of evaporative cooling and semiconductor refrigeration was designed. Principle and three modes of operation were discussed, and the design step of split air conditioner was summarized. The water and air temperature of split air conditioner were tested with the experimental prototype. The results show that the air temperature of outdoor unit is about 3-4 °C higher than outdoor wet bulb temperature. The water temperature of outdoor unit is about 1-2 °C lower than outdoor wet bulb temperature. After decreasing by semiconductor refrigeration again, it can be about 4-5 °C lower than the outdoor wet bulb temperature. According to the test results, combined with meteorological data, the air and water temperature in 228 cities in China was calculated. The calculated results show that the split evaporative air conditioner is widely adopted in Northwest China and other dry areas. The applicable rate is over 90%.
Available documents
Format PDF
Pages: 38-43
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30019768
- Languages: Chinese
- Source: Journal of Refrigeration - vol. 35 - n. 159
- Publication date: 2014/10
- DOI: http://dx.doi.org/10.3969/j.issn.0253-4339.2014.05.038
Links
See other articles in this issue (4)
See the source
Indexing
- Themes: Humidification/dehumidification equipment
- Keywords: Split system; Air conditioner; Design; Evaporative system; Testing; Part load
-
Study on annual performance of room air conditi...
- Author(s) : HORIE H., HIHARA E.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Evaluating the impact of the measurement setup ...
- Author(s) : DHUMANE R., QIU T., LING J., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Experimental study on performance of segmented ...
- Author(s) : JIANG X., LIANG C.
- Date : 2014/10
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 35 - n. 159
- Formats : PDF
View record
-
Leistungsnachweis und Diagnose des Betriebes ei...
- Author(s) : DKV, KNABE G., RATHEY A., WERDIN H.
- Date : 1997/11/19
- Languages : German
- Source: DKV-Tagungsbericht 24. 1997, Hamburg.
View record
-
Assessment of a desiccant cooling system as a v...
- Author(s) : BELDING W. A., DELMAS M. P. F., HOLEMAN W. D.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record