Document IIF
Conception et test de la récupération de chaleur pour un système de conditionnement d'air mobile à pompe à chaleur avec boucle secondaire.
Heat recovery design and test for the secondary loop heat pump MAC system.
Résumé
In mobile air conditioning (MAC) systems, the secondary loop (SL) structure was usually adopted when using flammable refrigerants such as R1234yf, R290 and R152a. The introduction of intermediate heat exchangers in SL system inevitably increased the temperature difference between the condensation side and the evaporation side, thereby increased the compressor power consumption and caused the performance attenuation. To overcome the attenuation, this study designed a heat recovery device which collects the waste heat from the passenger compartment to increase the evaporation temperature and reduce the compressor power consumption. Validation experiments were completed in a secondary loop heat pump (SLHP) MAC system using R152a and was compared with a baseline direct expansion (DX) system. According to experimental results, under the -10 °C outdoor temperature, the SLHP system showed performance attenuation compared with the DX system. With the increase in indoor temperature, the attenuation gradually increased to 8.96% at the indoor temperature of 20 °C. In this case, a heat recovery design was used in the SLHP system, which increased the coefficient of performance (COP) by 9.29% compared with the original SLHP system and achieved similar performance to the DX system.
Documents disponibles
Format PDF
Pages : 42-51
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Heat recovery design and test for the secondary loop heat pump MAC system.
- Identifiant de la fiche : 30028152
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 123
- Date d'édition : 03/2021
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.10.038
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (19)
Voir la source
Indexation
-
Experimental and numerical investigation of a C...
- Auteurs : WENG Y., WANG D., YU B., et al.
- Date : 04/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 100
- Formats : PDF
Voir la fiche
-
Experimental study on combined defrosting perfo...
- Auteurs : ZHOU G., LI H., LIU E., et al.
- Date : 04/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 116
Voir la fiche
-
Experimental comparison of R744 and R134a heat ...
- Auteurs : WANG Y., DONG J., JIA S., HUANG L.
- Date : 01/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 121
- Formats : PDF
Voir la fiche
-
An experimental investigation of oil circulatio...
- Auteurs : LI K., LUO S., WANG Z., SU L., FANG Y., ZHOU X., ZHANG H., TU R.
- Date : 02/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 122
- Formats : PDF
Voir la fiche
-
High-Efficiency HVAC System with Defog/Dehumidi...
- Auteurs : CHANG T. B., SHEU J. J., HUANG J. W.
- Date : 01/2021
- Langues : Anglais
- Source : Energies - vol. 14 - n. 1
- Formats : PDF
Voir la fiche