Document IIF
Condensation de vapeur saturée de R1234ze(Z) à l’intérieur d’un tube lisse horizontal de 4 mm de diamètre intérieur.
Saturated vapor condensation of R1234ze(Z) inside a 4 mm ID horizontal smooth tube.
Numéro : pap. n. 1141
Auteurs : LONGO G. A., MANCIN S., RIGHETTI G., et al.
Résumé
R1234ze(Z), cis-1,3,3,3-tetrafluoroprop-1-ene, has been proposed as a refrigerant for high temperature heat pumps. The application of this molecule is still not widespread and its heat transfer performance is still poorly investigated, in comparison to other HFO refrigerants. This paper presents the experimental heat transfer coefficient and frictional pressure drop measured during R1234ze(Z) saturated vapour condensation inside a 4 mm ID horizontal copper smooth tube. New experimental tests were carried out at 40 °C of saturation temperature, with refrigerant mass flux in the range 75–300 kg m -2 s -1 at decreasing vapour quality. The new data are then compared against some wellknown literature correlations and, finally, against other experimental data collected by using isobutane as two-phase fluid under the same saturation temperature and mass fluxes.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Saturated vapor condensation of R1234ze(Z) inside a 4 mm ID horizontal smooth tube.
- Identifiant de la fiche : 30024840
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.18462/iir.hfo.2018.1141
Liens
Voir d'autres communications du même compte rendu (126)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Mesures thermodynamiques;
HFC - Mots-clés : Tube horizontal; Coefficient de transfert de chaleur; Vapeur; R1234ze; HFO; Experimentation; Condensation; Chute de pression
-
Saturated vapor condensation of R1234ze(Z) insi...
- Auteurs : LONGO G. A., MANCIN S., RIGHETTI G., et al.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Caractéristiques du transfert de chaleur lors d...
- Auteurs : LI M., YANG Y., GU H., et al.
- Date : 08/2014
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 35 - n. 158
- Formats : PDF
Voir la fiche
-
Experimental study on heat transfer and pressur...
- Auteurs : KOYAMA S., BABA D., NAKAHATA H.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
R134a and its low GWP substitutes R1234yf and R...
- Auteurs : LONGO G. A., MANCIN S., RIGHETTI G., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
HFO-1234ze(E) flow boiling heat transfer inside...
- Auteurs : DIANI A., ROSSETTO L.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche