Conditionnement d'air à accumulation thermique dans les éléments de construction comportant des matériaux à changement de phase.

Acondicionamiento de aire con acumulación térmica en elementos de la edificación modificados con materiales con cambio de fase.

Auteurs : PRYMON M., SCHNOTALE J.

Type d'article : Article de périodique

Résumé

This article is the Spanish translation of an article presented at the 22nd IIR international Congress in Beijing, China (see the Bulletin of the IIR, reference 2007-2769). Air conditioning of residential and office buildings significantly contributes to electrical consumption and peak power demand, particularly in summertime. Thermal storage combined with night ventilation can be used to reduce energy consumption and peak-power demand as well as to downsize the refrigerating capacity of an air conditioning system. Energy efficiency and thermal capacity of such passive cooling systems based on thermal energy storage in building structure can be significantly improved by implementation of phase-change material (PCM) in building elements such as wall covering material (gypsum board, plaster) or ventilated ceiling made of modified rib-and-slab tiles. In the paper, a concept air conditioning system based on night ventilation and thermal storage in modified rib-and-slab tiles is presented. Microencapsulated PCM was utilized in order to increase the thermal capacity of the building elements. Numerical simulation was carried out as a preliminary study. A complex heat transfer and air flow model for a typical office room with ventilated ceiling was developed using computational fluid dynamic software. The thermal properties of the building material modified by PCM were obtained from inverse analyses. The numerical analysis was verified by laboratory measurement done in a calorimetric chamber where the thermal performance of modified by PCM and reference materials were tested. Test results indicated that the air-conditioning system investigated can improve the thermal performance of an office and/or residential buildings by lowering the overall energy consumption and carbon dioxide emissions associated with air conditioning operation. In a reference case study, an air-conditioning system for an office space with ceiling construction modified by PCM, to enhance thermal storage, demonstrated significant reduction of heat loads and energy consumption.

Documents disponibles

Format PDF

Pages : 60-68 (6 p.)

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Acondicionamiento de aire con acumulación térmica en elementos de la edificación modificados con materiales con cambio de fase.
  • Identifiant de la fiche : 2009-0334
  • Langues : Espagnol
  • Source : IIF-IIR/Frío Calor Aire acond. - vol. 36 - n. 407
  • Date d'édition : 10/2008

Liens


Voir d'autres articles du même numéro (5)
Voir la source